LEGEND MAX™ Human CCL17 (TARC) ELISA Kit

Pricing & Availability
Regulatory Status
RUO
Other Names
Human CCL17 (TARC) Precoated ELISA Kit, Thymus and activation-regulated chemokine (TARC), Small-inducible cytokine 17 (SCYA17), ABCD-2
Ave. Rating
Submit a Review
Product Citations
publications
CCL17_Human_ELISA_Kit_LegMax_083013
  • CCL17_Human_ELISA_Kit_LegMax_083013
Cat # Size Price Quantity Check Availability Save
441107 1 Pre-coated Plate $462
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Human CCL17, also known as thymus and activation regulated chemokine (TARC), was initially isolated from phytohemagglutinin-stimulated peripheral blood mononuclear cells. CCL17 is constitutively expressed in the thymus and under activation in several cell types. CCL17-mediated recruitment of Th2 cells and CLA+ CD4+ T cells plays a key role in allergic diseases such as atopic dermatitis, allergic asthma, allergic rhinitis, and allergic contact dermatitis. In addition, CCL17 has been detected in idiopathic pulmonary fibrosis. CCL17 and CCL22 secreted by dendritic cells (DCs) seems to mediate the recruitment of regulatory T cells to sites of inflammation in patients with chronic hepatitis. CCL17 is upregulated under several conditions: TNF-a, IL-4, and IFN-? in bronchial epithelial cells; TGF-ß1, TNF-a, and IFN-? in human keratinocyte cell lines; and histamine and prostaglandin E2P in immature DCs.

BioLegend's LEGEND MAX™ Human CCL17 (TARC) ELISA Kit is a Sandwich Enzyme-Linked Immunosorbent Assay (ELISA) with a 96-well strip plate that is pre-coated with an antibody specific for human CCL17. This kit is specifically designed for the accurate quantitation of human CCL17 from cell culture supernatant, serum, plasma, and other biological fluids. This kit is analytically validated with ready-to-use reagents.

Product Details
Technical data sheet

Kit Contents

Kit Contents
  • Anti-Human CCL17 (TARC) Pre-coated 96-well Strip Microplate
  • Human CCL17 (TARC) Dectection Antibody
  • Human CCL17 (TARC) Standard
  • Avidin-HRP D
  • Assay Buffer A
  • Wash Buffer (20X)
  • Substrate Solution F
  • Stop Solution
  • Plate Sealers

Product Details

Verified Reactivity
Human
Application

ELISA

Sensitivity
0.9 ± 0.12 pg/mL
Standard Range
7.8-500 pg/mL
Materials Not Included
  • Microplate reader able to measure absorbance at 450 nm
  • Adjustable pipettes to measure volumes ranging from 1 µL to 1,000 µL
  • Deionized water
  • Wash bottle or automated microplate washer
  • Log-Log graph paper or software for data analysis
  • Tubes to prepare standard dilutions
  • Timer
  • Plate Shaker
  • Polypropylene vials

Antigen Details

Cell Sources
PBMCs, monocytes, dendritic cells, bronchial epithelial cells, smooth muscle cells, keratinocytes, and fibroblasts
Biology Area
Cell Biology, Signal Transduction
Molecular Family
Cytokines/Chemokines
Gene ID
6361 View all products for this Gene ID
UniProt
View information about CCL17 on UniProt.org

Related FAQs

In your LEGEND MAX™ ELISA Kits, there is a step that calls for washing the plates before adding sample. What is the purpose of this step?

We typically use a stabilizer for pre-coated plates. The additional washing step is designed to remove these components before you start the assay. If you do not perform the washing, the effect on assay performance is negligible.

I have multiple LEGEND MAX™ ELISA kits that I want to run simultaneously. Can I use the same wash buffer for all the kits?

The wash buffer provided in all our LEGEND MAX™ kits is the same and the part numbers on the wash buffer bottles in these kits should be identical. For ELISA MAX™ Deluxe and ELISA MAX™ Standard Sets, we provide a recipe for the wash buffer on each kit’s technical data sheet. This recipe is the same for all ELISA MAX™ sets.

For some of your ELISA kits, why do my serum samples require dilution with assay buffer?

In some cases, dilution with assay buffer is required to minimize the matrix difference between the samples and the standards to achieve better accuracy.

Go To Top Version: 2    Revision Date: 09/11/2013

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login/Register
Remember me
Forgot your password? Reset Password
Request an Account