- Clone
- MHM-88 (See other available formats)
- Regulatory Status
- RUO
- Other Names
- Immunoglobulin M
- Isotype
- Mouse IgG1, κ
- Ave. Rating
- Submit a Review
- Product Citations
- publications
Cat # | Size | Price | Quantity Check Availability | Save | ||
---|---|---|---|---|---|---|
314527 | 100 µg | $129 |
IgM is the first immunoglobulin made by B cells in the immune response. Surface IgM is expressed on immature and mature B cells, while IgM heavy (μ) chain is expressed intracellularly in pre-B cells.
Product DetailsProduct Details
- Verified Reactivity
- Human
- Reported Reactivity
- African Green, Baboon, Cynomolgus, Rhesus
- Antibody Type
- Monoclonal
- Host Species
- Mouse
- Immunogen
- Human Ig cocktail
- Formulation
- Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and EDTA.
- Preparation
- The antibody was purified by affinity chromatography.
- Concentration
- 1.0 mg/ml
- Storage & Handling
- The antibody solution should be stored undiluted between 2°C and 8°C.
- Application
-
FC - Quality tested
CyTOF® - Verified - Recommended Usage
-
This product is suitable for use with the Maxpar® Metal Labeling Kits. For metal labeling using Maxpar® Ready antibodies, proceed directly to the step to Partially Reduce the Antibody by adding 100 µl of Maxpar® Ready antibody to 100 µl of 4 mM TCEP-R in a 50 kDa filter and continue with the protocol. Always refer to the latest version of Maxpar® User Guide when conjugating Maxpar® Ready antibodies.
- Application Notes
-
MHM-88 antibody reacts with both soluble and membrane human immunoglobulin M (IgM). It does not react with other Ig isotypes. Additional reported applications (for the relevant formats) include: use as a primary or secondary reagent for ELISA analysis.
Due to the presence of excess soluble IgM in whole blood, which competes for antibody binding, staining for IgM on cells in whole blood is not recommended. - Additional Product Notes
-
Maxpar® is a registered trademark of Standard BioTools Inc.
-
Application References
(PubMed link indicates BioLegend citation) -
- Perez-Shiyama C, et al. 2014. J Immunol. 192:5192. PubMed
- Product Citations
-
- RRID
-
AB_2563776 (BioLegend Cat. No. 314527)
Antigen Details
- Structure
- Ig family
- Distribution
-
B cells
- Function
- B cell differentiation, humoral immune response; cross-linking surface IgM induces apoptosis
- Cell Type
- B cells
- Biology Area
- Immunology
- Gene ID
- 3507 View all products for this Gene ID
- UniProt
- View information about IgM on UniProt.org
Related FAQs
- Can I obtain CyTOF data related to your Maxpar® Ready antibody clones?
-
We do not test our antibodies by mass cytometry or on a CyTOF machine in-house. The data displayed on our website is provided by Fluidigm®. Please contact Fluidigm® directly for additional data and further details.
- Can I use Maxpar® Ready format clones for flow cytometry staining?
-
We have not tested the Maxpar® Ready antibodies formulated in solution containing EDTA for flow cytometry staining. While it is likely that this will work in majority of the situations, it is best to use the non-EDTA formulated version of the same clone for flow cytometry testing. The presence of EDTA in some situations might negatively affect staining.
- I am having difficulty observing a signal after conjugating a metal tag to your Maxpar® antibody. Please help troubleshoot.
-
We only supply the antibody and not test that in house. Please contact Fluidigm® directly for troubleshooting advice: http://techsupport.fluidigm.com/
- Is there a difference between buffer formulations related to Maxpar® Ready and purified format antibodies?
-
The Maxpar® Ready format antibody clones are formulated in Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and EDTA. The regular purified format clones are formulated in solution that does not contain any EDTA. Both formulations are however without any extra carrier proteins.
Other Formats
View All IgM Reagents Request Custom ConjugationCustomers Also Purchased
Compare Data Across All Formats
This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.
-
Purified anti-human IgM
Over night cultured human peripheral blood lymphocytes stain... -
PE anti-human IgM
Human peripheral blood lymphocytes were stained with CD19 FI... -
Biotin anti-human IgM
Human peripheral blood lymphocytes stained with CD19 APC and... -
FITC anti-human IgM
Human peripheral blood lymphocytes stained with MHM-88 FITC -
APC anti-human IgM
Human peripheral blood lymphocytes stained with MHM-88 APC -
PerCP/Cyanine5.5 anti-human IgM
Overnight cultured human peripheral blood lymphocytes were s... -
Pacific Blue™ anti-human IgM
Over night cultured human peripheral blood lymphocytes stain... -
Brilliant Violet 421™ anti-human IgM
-
APC/Cyanine7 anti-human IgM
Human peripheral blood lymphocytes were cultured overnight a... -
Brilliant Violet 570™ anti-human IgM
Isolated human peripheral blood mononuclear cells were stain... -
Brilliant Violet 510™ anti-human IgM
Isolated human peripheral blood mononuclear cells were stain... -
Brilliant Violet 605™ anti-human IgM
Overnight cultured human peripheral blood mononuclear cells ... -
Brilliant Violet 650™ anti-human IgM
Overnight cultured human peripheral blood mononuclear cells ... -
Purified anti-human IgM (Maxpar® Ready)
Human PBMCs stained with 142Nd-anti-CD19 (HIB19) and 172Yb-a... -
PE/Dazzle™ 594 anti-human IgM
Overnight cultured human peripheral blood mononuclear cells ... -
PE/Cyanine7 anti-human IgM
Overnight cultured human peripheral blood mononuclear cells ... -
Alexa Fluor® 488 anti-human IgM
Overnight cultured human peripheral blood mononuclear cells ... -
Alexa Fluor® 647 anti-human IgM
Overnight cultured human peripheral blood mononuclear cells ... -
Alexa Fluor® 700 anti-human IgM
Overnight cultured human peripheral blood mononuclear cells ... -
Brilliant Violet 711™ anti-human IgM
Isolated human peripheral blood mononuclear cells were stain... -
TotalSeq™-A0136 anti-human IgM
-
TotalSeq™-C0136 anti-human IgM
-
Brilliant Violet 785™ anti-human IgM
Human peripheral blood lymphocytes were cultured overnight a... -
APC/Fire™ 750 anti-human IgM
Human peripheral blood lymphocytes were cultured overnight a... -
TotalSeq™-B0136 anti-human IgM
-
Spark Violet™ 423 anti-human IgM Antibody
Overnight cultured human peripheral blood lymphocytes were s... -
TotalSeq™-D0136 anti-human IgM
-
Spark Blue™ 550 anti-human IgM
Human peripheral blood lymphocytes were cultured overnight a... -
Spark Blue™ 515 anti-human IgM
Overnight cultured human peripheral blood mononuclear cells ... -
PE/Fire™ 700 anti-human IgM
Overnight cultured human peripheral blood mononuclear cells ... -
Spark YG™ 593 anti-human IgM
Overnight cultured human peripheral blood lymphocytes staine... -
PE/Fire™ 640 anti-human IgM
Human peripheral blood mononuclear cells were stained with a... -
Spark Red™ 718 anti-human IgM (Flexi-Fluor™)
-
APC anti-human IgM
Typical results from overnight cultured human peripheral blo... -
PE anti-human IgM
Typical results from overnight cultured human peripheral blo... -
Brilliant Violet 750™ anti-human IgM
Overnight cultured human peripheral blood mononuclear cells ...
Follow Us