Ultra-LEAF™ Purified anti-His Tag Antibody

Pricing & Availability
Clone
J099B12 (See other available formats)
Regulatory Status
RUO
Other Names
Histidine Tag
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
J099B12_ULEAF_HisTag_Antibody_WB_082417
0.1µl recombinant Posi-Tag Epitope Tag Protein was resolved by electrophoresis (4-12% Bis-Tris gel), transferred to nitrocellulose, and probed with 1:1000 diluted ( µg/mL) purified anti-His Tag antibody (clone J099B12) (upper). Proteins were visualized by chemiluminescence detection using 1:3000 diluted HRP Goat anti-mouse IgG antibody. Lane M is the molecular protein marker.
  • J099B12_ULEAF_HisTag_Antibody_WB_082417
    0.1µl recombinant Posi-Tag Epitope Tag Protein was resolved by electrophoresis (4-12% Bis-Tris gel), transferred to nitrocellulose, and probed with 1:1000 diluted ( µg/mL) purified anti-His Tag antibody (clone J099B12) (upper). Proteins were visualized by chemiluminescence detection using 1:3000 diluted HRP Goat anti-mouse IgG antibody. Lane M is the molecular protein marker.
Compare all formats
Cat # Size Price Quantity Check Availability Save
652507 100 µg $270
Check Availability


Need larger quantities of this item?
Request Bulk Quote
652508 1 mg $715
Check Availability


Need larger quantities of this item?
Request Bulk Quote

Select size of product is eligible for a 40% discount! Promotion valid until December 31, 2024. Exclusions apply. To view full promotion terms and conditions or to contact your local BioLegend representative to receive a quote, visit our webpage.

Description

This antibody was raised against linear 8XHis tag. It reacts with His tag protein, either C, N, or internal His6 and up repeats. It can be used for Western blotting to detect linear His repeat (His6 or more).

Product Details
Technical data sheet

Product Details

Verified Reactivity
Epitope tag
Reported Reactivity
Species independent
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
KLH-conjugated His-tag peptide
Formulation
0.2 µm filtered in phosphate-buffered solution, pH 7.2, containing no preservative.
Endotoxin Level
Less than 0.01 EU/µg of the protein (< 0.001 ng/µg of the protein) as determined by the LAL test.
Preparation
The Ultra-LEAF™ (Low Endotoxin, Azide-Free) antibody was purified by affinity chromatography.
Concentration
The antibody is bottled at the concentration indicated on the vial, typically between 2 mg/mL and 3 mg/mL. Older lots may have also been bottled at 1 mg/mL. To obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C. This Ultra-LEAF™ solution contains no preservative; handle under aseptic conditions. Do not freeze.
Application

WB -Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by Western blotting. For Western blotting, the suggested use of this reagent is 1:1000-1:10000 diluted (0.1 - 1.0 µg/mL). It is recommended that the reagent be titrated for optimal performance for each application. 

Application References

(PubMed link indicates BioLegend citation)
  1. Burritt JB, et al. 1995. J. Biol. Chem. 270:16974.
  2. Taylor RM, et al. 2007. Methods Mol. Biol. 412:429.
RRID
AB_2716060 (BioLegend Cat. No. 652507)
AB_2716060 (BioLegend Cat. No. 652508)

Antigen Details

Function
Recombinant poly-histidine tag detection
Biology Area
Cell Biology
Gene ID
NA
UniProt
View information about His Tag on UniProt.org

Related FAQs

Do you guarantee that your antibodies are totally pathogen free?

BioLegend does not test for pathogens in-house aside from the GoInVivo™ product line. However, upon request, this can be tested on a custom basis with an outside, independent laboratory.

Does BioLegend test each Ultra-LEAF™ antibody by functional assay?

No, BioLegend does not test Ultra-LEAF™ antibodies by functional assays unless otherwise indicated. Due to the possible complexities and variations of uses of biofunctional antibodies in different assays and because of the large product portfolio, BioLegend does not currently perform functional assays as a routine QC for the antibodies. However, we do provide references in which the antibodies were used for functional assays and we do perform QC to verify the specificity and quality of the antibody based on our strict specification criteria.

Does BioLegend test each Ultra-LEAF™ antibody for potential pathogens?

No, BioLegend does not test for pathogens in-house unless otherwise indicated.  However, we can recommend an outside vendor to perform this testing as needed.

Have you tested this Ultra-LEAF™ antibody for in vivo or in vitro applications?

We don't test our antibodies for in vivo or in vitro applications unless otherwise indicated. Depending on the product, the TDS may describe literature supporting usage of a particular product for bioassay. It may be best to further consult the literature to find clone specific information.

Go To Top Version: 2    Revision Date: 09/21/2023

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login/Register
Remember me
Forgot your password? Reset Password
Request an Account