Zombie Green™ Fixable Viability Kit

Pricing & Availability
Regulatory Status
RUO
Other Names
Fixable Dye, Fixable Viability Dye
Ave. Rating
Submit a Review
Product Citations
publications
a-Zombie_Green_Viability_Dye_012714
One day old C57BL/6 mouse splenocytes were stained with Zombie Green™ and analyzed before fixation (purple) or after fixation and permeabilization (red). Cells alone, without Zombie Green™ staining, are indicated in black.
  • a-Zombie_Green_Viability_Dye_012714
    One day old C57BL/6 mouse splenocytes were stained with Zombie Green™ and analyzed before fixation (purple) or after fixation and permeabilization (red). Cells alone, without Zombie Green™ staining, are indicated in black.
  • b_Zombie_Green_Kit_ICC_012721
    HeLa cells were treated with 20% EtOH for 20 seconds, washed twice with PBS, and then were left to recover for five minutes with cell culture media in 37°C. The cells were stained with Zombie Green™ (1:1000) (green) for 15 minutes and then fixed with 1% paraformaldehyde (PFA) for ten minutes. Nuclei were counterstained with DAPI (blue) for five minutes. The image was captured with 40X objective.
See Zombie Green™ spectral data
Cat # Size Price Quantity Check Availability Save
423111 100 tests $89
Check Availability


Need larger quantities of this item?
Request Bulk Quote
423112 500 tests $335
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

Zombie Green™ is an amine-reactive fluorescent dye that is non-permeant to live cells but permeant to the cells with compromised membranes. Thus, it can be used to assess live vs. dead status of mammalian cells. Zombie Green™ is a polar, water soluble dye providing green fluorescence, making it suitable for multi-color detection.

Product Details
Technical data sheet

Product Details

Preparation
Zombie Green™ Fixable Viability Kit is composed of lyophilized Zombie Green™ dye and anhydrous DMSO. For reconstitution, bring the kit to room temperature; add 100 µl of DMSO to one vial of Zombie Green™ dye until fully dissolved. 100 tests = 1 vial of Zombie Green™ + DMSO, 500 tests = 5 vials of Zombie Green™ + DMSO.
Storage & Handling
Store kit at -20°C upon receipt. Do not open vials until needed. Once the DMSO is added to the Zombie Green™ dye, use immediately, or store at -20°C in a dry place and protected from light, preferably in a desiccator or in a container with desiccant for no more than one month.
Application

FC, ICFC - Quality tested
ICC - Verified

Recommended Usage

Each lot of this product is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometry, the suggested dilution is 1:100-1:1000 for 1-10 million cells. For immunocytochemistry, the suggested dilution is 1:1000. It is recommended that the reagent be titrated for optimal performance for each application, as optimal dosage varies with cell type.


This product is provided under an intellectual property license from Life Technologies Corporation.

View full statement regarding label licenses
Excitation Laser
Blue Laser (488 nm)
Application Notes

Zombie Green™ dye is excited by the blue laser (488 nm) and has a fluorescence emission maximum of 515 nm. If using in a multi-color panel design, filter optimization may be required depending on other fluorophores used. Zombie Green™ dye has similar emission to FITC.

Standard Cell Staining Protocol:

  1. Prior to reconstitution, spin down the vial of lyophilized reagent in a microcentrofuge to ensure the reagent is at the bottom of the vial.
  2. For reconstitution, pre-warm the kit to room temperature; add 100 µL of DMSO to one vial of Zombie Green™ dye and mix until fully dissolved
  3. Wash cells with PBS buffer (no Tris buffer and protein free).
  4. Dilute Zombie Green™ dye at 1:100-1000 in PBS. Resuspend 1-10 x 106 cells in diluted 100 µL Zombie Green™ solution. To minimize background staining of live cells, titrate the amount of dye and/or number of cells per 100 µL for optimal performance. Different cell types can have a wide degree of variability in staining based on cell size and degree of cell death.
    • Note: Don’t use Tris buffer as a diluent and be sure that the PBS does not contain any other protein like BSA or FBS.
    • Note: The amount of dye used can also influence the ability to detect apoptotic as well as live and dead cells.
  5. Incubate the cells at room temperature (or 4°C), in the dark, for 15-30 minutes.
  6. Wash one time with 2 mL BioLegend’s Cell Staining Buffer (Cat. No. 420201) or equivalent buffer containing serum or BSA.
  7. Continue performing antibody staining procedure as desired.
  8. Cells can be fixed with paraformaldehyde or methanol prior to permeabilization or can be analyzed without fixation.

No-wash Sequential Staining Protocol:

  1. Wash cells with PBS buffer (no Tris buffer and protein free).
  2. For reconstitution, pre-warm the kit to room temperature; add 100 µL of DMSO to one vial of Zombie Green™ dye and mix until fully  dissolved
  3. Determine the total µL volume of antibody cocktail previously titrated and optimized for the assay that will be added to each vial/well of cells based on a final volume of 100 µL. Subtract that antibody volume from the 100 µL total staining volume intended for the assay. In the remaining volume, dilute Zombie Green™ dye at 1:100-1000 in PBS as determined by prior optimization at that volume. For example, if you are adding 20 µL of antibody cocktail for a 100 µL total staining volume, use 80 µL of Zombie Green™ solution. Resuspend 1-10 x 106 cells in the appropriate volume of Zombie Green™ solution. Different cell types can have a wide degree of variability in staining based on cell size and degree of cell death.
    • Note: Don’t use Tris buffer as a diluent and be sure that the PBS does not contain any other protein like BSA or FBS.
    • Note: The amount of dye used can also influence the ability to detect apoptotic as well as live and dead cells.
  4. Incubate for 10-15 minutes at RT (or 4°C), protected from light. Without washing the cells, add the cell surface antibody cocktail and incubate for another 15-20 minutes.
  5. Add 1-2 mL Cell Staining Buffer (Cat. No. 420201) or equivalent buffer containing BSA or serum. Centrifuge to pellet.
  6. Continue with normal fixation and permeabilization procedure. If planning to skip fixation and analyze cells live, complete an additional wash step to minimize any unnecessary background of the live cells.
    • Notes: If the cell type in use cannot tolerate a protein-free environment, then titrate the Zombie Green™ dye in the presence of the same amount of BSA/serum as will be present in the antibody staining procedure. A higher amount of Zombie Green™ may be required since the BSA/serum will react with and bind up some proportion of the Zombie Green™.
Additional Product Notes

View more applications data for this product in our Scientific Poster Library.

Product Citations
  1. Iraolagoitia X, et al. 2016. J Immunol. 197: 953 - 961. PubMed
  2. Knelson EH, et al. 2022. Cancer Immunol Res. 10:947. PubMed
  3. Li K, et al. 2022. Cancer Cell. 40:1374. PubMed
  4. You S, et al. 2023. Sci Adv. 9:eade7923. PubMed
  5. Evans JG, et al. 2023. Viruses. 15:. PubMed
  6. Amodeo V, et al. 2023. Dev Cell. 58:836. PubMed
  7. Tereshko L, et al. 2021. Elife. 10: . PubMed
  8. Martínez-Vélez N, et al. 2022. Mol Cancer Ther. 21:471. PubMed
  9. Hsu MA, et al. 2022. Cancer Immunol Immunother. :. PubMed
  10. Sweeney-Ambros AR, et al. 2022. J Orthop Res. 40:2843. PubMed
  11. Atalis A, et al. 2022. J Control Release. 347:476. PubMed
  12. Podico G, et al. 2022. Animals (Basel). 12: . PubMed
  13. Foo CX, et al. 2023. Eur Respir J. 61: . PubMed
  14. Li S, et al. 2022. Nat Commun. 13:7371. PubMed
  15. Subedi N, et al. 2022. Adv Biol (Weinh). :e2200207. PubMed
  16. Taniguchi S, et al. 2023. Nat Commun. 14:143. PubMed
  17. Gonçalves R, et al. 2023. iScience. 26:105972. PubMed
  18. Tsioti I, et al. 2023. J Neuroinflammation. 20:25. PubMed
  19. Donado CA, et al. 2020. Cell Reports. 31(1):107466. PubMed
  20. Muire P, et al. 2017. PLoS One. 10.1371/journal.pone.0184077. PubMed
  21. Mayer RL, et al. 2022. Nat Commun. 13:6075. PubMed
  22. van der Heide V, et al. 2022. Cell Rep. :110508. PubMed
  23. Gärtner F, et al. 2021. Front Immunol. 12:745132. PubMed
  24. Paprckova D, et al. 2022. Front Immunol. 13:1009198. PubMed
  25. Ireland AS, et al. 2020. Cancer Cell. 38:60. PubMed
  26. Akabane S, et al. 2016. J Biol Chem. 291: 16162 - 16174. PubMed
  27. Kelsey E Sivick et al. 2018. Cell reports. 25(11):3074-3085 . PubMed
  28. Freemerman AJ, et al. 2019. J Immunol. 202:1265. PubMed
  29. Darnaud M, et al. 2021. Nat Commun. 12:6686. PubMed
  30. Agarwal P, et al. 2021. Heliyon. 7:e06210. PubMed
  31. Krauss PL, et al. 2021. Front Immunol. 12:730672. PubMed
  32. Bhatt B, et al. 2020. Methods Mol Biol. 2121:93. PubMed
  33. Swartz AM, et al. 2022. Curr Protoc. 2:e410. PubMed
  34. Brennan FH, et al. 2022. Nat Commun. 13:4096. PubMed
  35. Ercoli G, et al. 2022. Clin Transl Immunology. 11:e1366. PubMed
  36. Li K, et al. 2021. Sci Adv. 7: . PubMed
  37. Van Eyndhoven LC, et al. 2021. Front Immunol. 12:672729. PubMed
  38. Garcia-Valtanen P, et al. 2022. Cell Rep Med. 3:100651. PubMed
  39. Peña FJ, et al. 2018. Cytometry B Clin Cytom. 94:302. PubMed
  40. Fabian P, et al. 2022. Nat Commun. 13:13. PubMed
  41. Rubin SJS, et al. 2019. Nat Commun. 10:2686. PubMed
  42. Meyrath M, et al. 2020. Nat Commun. 2.564583333. PubMed
  43. Lago-Alvarez Y, et al. 2020. Animals (Basel). 10:00. PubMed
  44. Kaddatz H, et al. 2020. Glia. 69:925. PubMed
  45. Ma Q, et al. 2022. Vaccines (Basel). 10:. PubMed
  46. Zufferey R, et al. 2017. PLoS One. 10.1371/journal.pone.0181432. PubMed
  47. Cho S, et al. 2019. Transl Oncol. 0.820138889. PubMed
  48. Segabinazzi LGTM, et al. 2021. Antibiotics (Basel). 10: . PubMed
  49. Jatho A, et al. 2022. Cells. 11:. PubMed
  50. Zheng W, et al. 2019. Cell Rep. 29:1747. PubMed
  51. Orozco SL, et al. 2019. Cell Rep. 28:2275. PubMed

Antigen Details

Biology Area
Apoptosis/Tumor Suppressors/Cell Death, Cell Biology, Neuroscience
Gene ID
NA

Related FAQs

I am concerned about the spillover I am observing from the Zombie dye into its neighboring channels.
Rule of thumb with Zombie dyes is to titrate them down as much as possible to fit your application. This should potentially help with spillover. Secondly, Zombie positive events represent dead cells and are typically gated out from analysis.
How does the performance of your Zombie dye compare with competitors?

Zombie dyes have been tested against other leading competitors' fixable viability kits and given comparable results. We also highly recommend that you titrate down the amount of each dye used in order to best match the negative signals of your unstained sample and MFI- (mean fluorescence intensity) stained samples.

Can I use methanol/ethanol for fixation after using a Zombie dye?

Yes, most fixation reagents are fine to be used with Zombie dyes. However, it should be noted that Zombie dyes can still be sensitive to reactive oxygen species. Light exposure or reagents with hydrogen peroxide can lead to free radical formation, affecting fluorescence.

Can Zombie be used to determine bacteria, yeast viability?
We have not tested in house bacterial or yeast viability using Zombie dyes. It is not clear whether the difference between surface and intracellular signals will be significantly different in case of non mammalian cells.
Can I use Zombie with cells suspension containing serum?
Serum is full of proteins which will sequester the dye and thereby reducing its effective concentration. The basic rule of thumb with zombie is to titrate it based on your specific condition. Titration also helps reduce the background and spillover into other channels.
Can I use Zombie dyes for microscopy?

Zombie dyes tested in-house for microscopy applications will display data on the product technical datasheet. It should be noted that Zombie dyes may not work for dead cell discrimination in every microscopy application. Important considerations that may impact analysis are determining the signal level that constitutes a dead cell and identifying the proper plane to observe the dead cells.

Why can't I fix my cells prior to using Zombie dyes?

The fixation process can contort and alter the membrane of cells, effectively rendering them dead. Since the ability of the Zombie dyes to stain dead cells is correlated with cell permeability, your results may no longer be a valid representation of dead versus live cells.

Can I use Zombie dyes to detect apoptotic cells?

Yes, Zombie dyes can be used with apoptosis markers, such as Annexin V or Apotracker™ (shown below), to discriminate live, apoptotic, and dead cells.

One day-old C57BL/6 mouse thymocytes were stained with Apotracker™ Tetra Alexa Fluor® 647 and Zombie™ YG581. Zombie-dim/Apotracker™-positive cells are apoptotic, while double-positive cells are dead. Live cells are negative for both markers.

How should I store Zombie dyes?

Store the Zombie dye kit at -20°C upon receipt. Do not open vials until needed. Once DMSO is added, use immediately or store at -20°C in a dry place and protected from light, preferably in a desiccator or in a container with desiccant for no more than one month.

Go To Top Version: 7    Revision Date: 12/18/2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

ProductsHere

Login/Register
Remember me
Forgot your password? Reset Password
Request an Account