Alexa Fluor® 700 anti-human CD19 Antibody

Pricing & Availability
Clone
HIB19 (See other available formats)
Regulatory Status
RUO
Workshop
V CD19.11
Other Names
B4
Isotype
Mouse IgG1, κ
HIB19_Alx700_022008
Human peripheral blood lymphocytes stained with HIB19 Alexa Fluor® 700
  • HIB19_Alx700_022008
    Human peripheral blood lymphocytes stained with HIB19 Alexa Fluor® 700
Compare all formats See Alexa Fluor® 700 spectral data
Cat # Size Price Quantity Check Availability
302225 25 µg $126.00
Check Availability


Need larger quantities of this item?
Request Bulk Quote
302226 100 µg $268.00
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD19 is a 95 kD type I transmembrane glycoprotein also known as B4. It is a member of the immunoglobulin superfamily expressed on B-cells (from pro-B to blastoid B cells, absent on plasma cells) and follicular dendritic cells. CD19 is involved in B cell development, activation, and differentiation. CD19 forms a complex with CD21 (CR2) and CD81 (TAPA-1), and functions as a BCR co-receptor.

Technical data sheet

Product Details

Verified Reactivity
Human
Reported Reactivity
Chimpanzee
Antibody Type
Monoclonal
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography and conjugated with Alexa Fluor® 700 under optimal conditions.
Concentration
0.5 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. The suggested use of this reagent is ≤1.0 µg per million cells in 100 µl volume. It is highly recommended that the reagent be titrated for optimal performance for each application.

* Alexa Fluor® 700 has a maximum emission of 719 nm when it is excited at 633 nm / 635 nm. Prior to using Alexa Fluor® 700 conjugate for flow cytometric analysis, please verify your flow cytometer's capability of exciting and detecting the fluorochrome.


Alexa Fluor® and Pacific Blue™ are trademarks of Life Technologies Corporation.

View full statement regarding label licenses
Excitation Laser
Red Laser (633 nm)
Application Notes

Additional reported applications (for the relevant formats) include: immunohistochemical staining of acetone-fixed frozen tissue sections8 and blocking of B cell proliferation. Clone HIB19 is not recommended for formalin-fixed paraffin-embedded sections. The Ultra-LEAF™ purified antibody (Endotoxin < 0.01 EU/µg, Azide-Free, 0.2 µm filtered) is recommended for functional assays (Cat. No. 302267 & 302268).

 

Clone HIB19 partially blocks anti-human CD19 clones 4G7 and SJ25C1 staining based on in-house testing

Application References

(PubMed link indicates BioLegend citation)
  1. Schlossman S, et al. 1995. Leucocyte Typing V. Oxford University Press. New York.
  2. Knapp W, et al. 1989. Leucocyte Typing IV. Oxford University Press. New York.
  3. Bradbury L, et al. 1993. J. Immunol. 151:2915.
  4. Joseph A, et al. 2010. J. Virol. 84:6645. PubMed
  5. Wang X, et al. 2010. Haematologica. 95:884. (FC) PubMed
  6. Walker JD, et al. 2009. J. Immunol. 182:1548. (Block) PubMed
  7. Yoshino N, et al. 2000. Exp. Anim. (Tokyo) 49:97. (FC)
  8. Hansen A, et al. 2002. Arthritis Rheum. 46:2160. (IHC)
  9. Stoeckius M, et al. 2017. Nat. Methods. 14:865. (PG)
  10. Peterson VM, et al. 2017. Nat. Biotechnol. 35:936. (PG)
Product Citations
  1. Wildner NH, et al. 2021. J Leukoc Biol. 109:77. PubMed
  2. Sefik E, et al. 2022. Nature. 606:585. PubMed
  3. Du Y, et al. 2022. J Exp Med. 219: . PubMed
  4. Viny AD, et al. 2019. Cell Stem Cell. 25:682. PubMed
  5. Ivan Jelcic et al. 2018. Cell. 175(1):85-100 . PubMed
  6. Fasbender F, et al. 2017. Front Immunol. 0.88125. PubMed
  7. Schmitz T, et al. 2021. J Reprod Immunol. 148:103424. PubMed
  8. Brouwer PJM, et al. 2020. Science. 369:643. PubMed
  9. Quast I, et al. 2015. Neurol Neuroimmunol Neuroinflamm. 2: e148. PubMed
  10. Wang J, et al. 2020. Cell. 183:1264. PubMed
  11. Jagannathan P, et al. 2017. Sci Rep. 10.1038/s41598-017-10624-3. PubMed
  12. Tardif V, et al. 2019. Nat Commun. 10:823. PubMed
  13. Feldman J, et al. 2021. Sci Immunol. 6:eabl5842. PubMed
  14. Shin JJ, et al. 2022. J Clin Immunol. :. PubMed
  15. Boyle M, et al. 2015. J Infect Dis. 212: 416-425. PubMed
  16. Miles B, et al. 2015. Nat Commun. 6: 8608. PubMed
  17. Rubio-Pérez C, et al. 2021. Nat Commun. 1503:12. PubMed
  18. Caduff N, et al. 2021. Cell Reports. 35(5):109056. PubMed
  19. Ramos RN, et al. 2022. Clin Transl Immunology. 11:e1392. PubMed
  20. Urlaub D, et al. 2019. Arthritis Res Ther. 1.067361111. PubMed
  21. Sefik E, et al. 2021. Nat Biotechnol. . PubMed
  22. Port JR, et al. 2020. J Virol. 94:. PubMed
  23. Gorman JA, et al. 2019. Front Immunol. 10:44. PubMed
  24. Berry MR et al. 2017. Cell. 170(5):860-874 . PubMed
  25. Shin CH, et al. 2020. J Immunol. 205:3179. PubMed
  26. Hood SP, et al. 2020. Elife. 9:00. PubMed
  27. Teng F, et al. 2021. Cell Rep. 37:110051. PubMed
  28. Plum T, et al. 2020. Immunity. 52(2):404-416. PubMed
  29. Harris LD, et al. 2020. Front Cell Infect Microbiol. 10:120. PubMed
  30. Inglis H, et al. 2015. J Vis Exp. 97: 52484. PubMed
  31. Serr I, et al. 2016. Nat Commun. 7:10991. PubMed
  32. Faissner S, et al. 2022. Front Immunol. 13:980526. PubMed
RRID
AB_493750 (BioLegend Cat. No. 302225)
AB_493750 (BioLegend Cat. No. 302226)

Antigen Details

Structure
Ig superfamily, type I transmembrane glycoprotein, 95 kD
Distribution

B lineage (except plasma cells), follicular dendritic cells

Function
B cell activation and differentiation
Ligand/Receptor
Forms complex with CD21 (CR2) and CD81 (TAPA-1), BCR coreceptor
Cell Type
B cells, Dendritic cells
Biology Area
Costimulatory Molecules, Immunology
Molecular Family
CD Molecules
Antigen References

1. Tedder T, et al. 1994. Immunol. Today 15:437.
2. Bradbury L, et al. 1993. J. Immunol. 151:2915.

Gene ID
930 View all products for this Gene ID
UniProt
View information about CD19 on UniProt.org

Other Formats

View All CD19 Reagents Request Custom Conjugation
Description Clone Applications
APC anti-human CD19 HIB19 FC
Biotin anti-human CD19 HIB19 FC
FITC anti-human CD19 HIB19 FC
PE anti-human CD19 HIB19 FC
PE/Cyanine5 anti-human CD19 HIB19 FC
Purified anti-human CD19 HIB19 FC,CyTOF®,IHC-F
APC/Cyanine7 anti-human CD19 HIB19 FC
PE/Cyanine7 anti-human CD19 HIB19 FC
Alexa Fluor® 488 anti-human CD19 HIB19 FC,ICC
Alexa Fluor® 647 anti-human CD19 HIB19 FC,IHC-F
Pacific Blue™ anti-human CD19 HIB19 FC
Alexa Fluor® 700 anti-human CD19 HIB19 FC
PerCP anti-human CD19 HIB19 FC
PerCP/Cyanine5.5 anti-human CD19 HIB19 FC
Brilliant Violet 421™ anti-human CD19 HIB19 FC,ICC,IHC-F
Brilliant Violet 570™ anti-human CD19 HIB19 FC
Brilliant Violet 650™ anti-human CD19 HIB19 FC
Brilliant Violet 785™ anti-human CD19 HIB19 FC
Brilliant Violet 510™ anti-human CD19 HIB19 FC
Brilliant Violet 605™ anti-human CD19 HIB19 FC
Brilliant Violet 711™ anti-human CD19 HIB19 FC
Purified anti-human CD19 (Maxpar® Ready) HIB19 FC,CyTOF®
Alexa Fluor® 594 anti-human CD19 HIB19 ICC,IHC-F
PE/Dazzle™ 594 anti-human CD19 HIB19 FC
PE anti-human CD19 HIB19 FC
APC/Fire™ 750 anti-human CD19 HIB19 FC
Pacific Blue™ anti-human CD19 HIB19 FC
APC anti-human CD19 HIB19 FC
PE/Cyanine7 anti-human CD19 HIB19 FC
TotalSeq™-A0050 anti-human CD19 HIB19 PG
Brilliant Violet 750™ anti-human CD19 HIB19 FC
TotalSeq™-B0050 anti-human CD19 HIB19 PG
TotalSeq™-C0050 anti-human CD19 HIB19 PG
PerCP/Cyanine5.5 anti-human CD19 HIB19 FC
Spark NIR™ 685 anti-human CD19 HIB19 FC
Ultra-LEAF™ Purified anti-human CD19 HIB19 FC,CyTOF®,Block,IHC
APC/Fire™ 810 anti-human CD19 HIB19 FC
PE/Fire™ 640 anti-human CD19 HIB19 FC
PE/Fire™ 700 anti-human CD19 HIB19 FC
TotalSeq™-D0050 anti-human CD19 HIB19 PG
Spark YG™ 593 anti-human CD19 HIB19 FC
GMP Pacific Blue™ anti-human CD19 HIB19 FC
Spark Violet™ 423 anti-human CD19 HIB19 FC
GMP PE anti-human CD19 HIB19 FC
GMP APC anti-human CD19 HIB19 FC
KIRAVIA Blue 520™ anti-human CD19 HIB19 FC
GMP PerCP/Cyanine5.5 anti-human CD19 HIB19 FC
GMP PE/Cyanine7 anti-human CD19 HIB19 FC
Spark Violet™ 500 anti-human CD19 HIB19 FC
PE/Fire™ 810 anti-human CD19 HIB19 FC
Spark Violet™ 423 anti-human CD19 HIB19 FC
Spark UV™ 387 anti-human CD19 HIB19 FC
APC/Fire™ 750 anti-human CD19 HIB19 FC
PE/Cyanine5 anti-human CD19 HIB19 FC
Alexa Fluor® 660 anti-human CD19 HIB19 FC
PerCP/Fire™ 806 anti-human CD19 HIB19 FC
PerCP/Fire™ 780 anti-human CD19 HIB19 FC
Spark PLUS UV395™ anti-human CD19 HIB19 FC
Spark Red™ 718 anti-human CD19 HIB19 FC
FITC anti-human CD19 HIB19 FC
Go To Top Version: 3    Revision Date: 06/27/2014

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

Login/Register
Forgot your password? Reset Password
Request an Account