Spark Blue™ 574 anti-human CD62L (Flexi-Fluor™) Antibody

Pricing & Availability
Clone
DREG-56 (See other available formats)
Regulatory Status
RUO
Workshop
V S056
Other Names
L-selectin, LECAM-1, LAM-1, Leu-8, TQ-1
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price Quantity Save
285168 50 µg 394 CHF
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD62L is a 74-95 kD single chain type I glycoprotein referred to as L-selectin or LECAM-1. It is expressed on most peripheral blood B cells, subsets of T and NK cells, monocytes, granulocytes, and certain hematopoietic malignant cells. CD62L binds to carbohydrates present on certain glycoforms of CD34, glycam-1, and MAdCAM-1 and with a low affinity to anionic oligosaccharide sequences related to sialylated Lewis X (sLex, CD15s) through its C-type lectin domain. CD62L is important for the homing of naïve lymphocytes to high endothelial venules in peripheral lymph nodes and Peyer's patches. It also plays a role in leukocyte rolling on activated endothelial cells.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human
Reported Reactivity
Chimpanzee, Cow
Antibody Type
Monoclonal
Host Species
Mouse
Immunogen
Concentrated supernatant from PMA-activated human peripheral blood leukocytes
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with Spark Blue™ 574 under optimal conditions.
Concentration
0.2 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC

Recommended Usage

Flexi-Fluors™ are provided at a standard 0.2 mg/mL concentration. We recommend titrating this reagent to determine the optimal concentration for each application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL. We recommend testing a range of concentrations starting from 10 µg/mL.

For example, make five 1:1 serial dilutions of the 0.2 mg/mL antibody. Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/mL) to test six concentrations -- 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration.

Excitation Laser
Blue Laser (488 nm)
Application Notes

Additional reported applications (for the relevant formats) include: Western blotting2,3,9 and in vitro blocking of lymphocytes binding to high endothelial venules (HEV)2. The Ultra-LEAF™ purified antibody (Endotoxin < 0.01 EU/µg, Azide-Free, 0.2 µm filtered) is recommended for functional assays (Cat. Nos. 304853-304858).

Additional Product Notes

For more information about Flexi-Fluors™, visit our Flexi-Fluor™ page and review FAQs associated with this product line.

Application References

(PubMed link indicates BioLegend citation)
  1. Schlossman S, et al. Eds. 1995. Leucocyte Typing V. Oxford University Press. New York.
  2. Kishimoto TK, et al. 1990. Proc. Natl. Acad. Sci. USA 87:2244. (WB, Block)
  3. Jutila M, et al. 2002. J. Immunol. 169:1768. (WB)
  4. Tamassia N, et al. 2008. J. Immunol. 181:6563. (FC) PubMed
  5. Kmieciak M, et al. 2009. J. Transl. Med. 7:89. (FC) PubMed
  6. Thakral D, et al. 2008. J. Immunol. 180:7431. (FC) PubMed
  7. Charles N, et al. 2010. Nat. Med. 16:701. (FC) PubMed
  8. Yoshino N, et al. 2000. Exp. Anim. (Tokyo) 49:97. (FC)
  9. Koenig JM, et al. 1996. Pediatr. Res. 39:616. (WB)
  10. Shi C, et al. 2011. J. Immunol. 187:5293. (FC) PubMed
  11. Burges M, et al. 2013. Clin Cancer Res. 19:5675. PubMed
  12. Cash JL, et al. 2013. EMBO Rep. 14:999. (FC) PubMed

Antigen Details

Structure
Selectin, single chain glycoprotein, 74-95 kD
Distribution

Majority of B cells, naïve T cells, subset of memory T and NK cells, monocytes, granulocytes, thymocytes

Function
Leukocyte homing, leukocyte tethering, rolling
Ligand/Receptor
CD34, GlyCAM, MAdCAM-1
Cell Type
B cells, Granulocytes, Monocytes, Neutrophils, NK cells, T cells, Thymocytes, Tregs
Biology Area
Cell Adhesion, Cell Biology, Costimulatory Molecules, Immunology, Innate Immunity
Molecular Family
Adhesion Molecules, CD Molecules
Antigen References
  1. Kishimoto T, et al. 1990. P. Natl. Acad. Sci. USA 87:2244.
  2. Kishimoto T, et al. 1991. Blood 78:805.

 

Gene ID
NA
UniProt
View information about CD62L on UniProt.org

Related FAQs

What are Flexi-Fluors?

Flexi-Fluors are rapidly made-to-order conjugated antibodies. The technology, manufacturing processes, and specifications used to create Flexi-Fluors are the same as our regular catalog products. However, the optimal concentration and performance of each Flexi-Fluor must be determined by the customer. 

How quickly will I receive my order?

We aim to ship Flexi-Fluors within 2-3 weeks of receipt of your order. However, depending on your location, shipping times may vary. 

How are Flexi-Fluors different from regular catalog products?

Flexi-Fluors are made on demand, specifically for you. Flexi-Fluors are manufactured using the same high-quality standards, and specifications as other catalog products. For faster delivery, Flexi-Fluors are not tested by flow cytometry to determine optimal concentrations or evaluate performance. This testing needs to be performed by the customer.

How do I determine the optimal concentration for using my Flexi-Fluor? How should I titrate my antibody?

Flexi-Fluors are provided at a standard 0.2 mg/mL concentration. We recommend that you titrate your antibody to determine the optimal concentration to use for your application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL volume. We recommend that you test a range of concentrations starting from 10 µg/mL. 

 

For example, make five 1:1 serial dilutions of your 0.2 mg/mL antibody.  Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/ml) to test six concentrations - 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration. 

I can’t find the antibody-dye combination that I need. When will it be available?

We continuously update our catalog, introducing scores of new products every month. Please get in touch with our Technical Service team for an update on new products or recommendations for suitable alternatives to complete your panel. Or contact Custom Solutions to inquire about our affordable custom conjugation services. 

I need help to validate the performance of my Flexi-Fluor. Who should I contact?

Please get in touch with Technical Service for assistance. 

Can I order more than 50 μg of a Flexi-Fluor?

Yes, you can order multiple vials of the same Flexi-Fluor products.  We cannot guarantee, however, that these vials will be bottled from the same lot. For bulk single-lot orders, contact our Custom Solutions team.

What is the expiration date of my Flexi-Fluor?

Expiration dates can be found on the vial label or by using our CoA lookup tool

Other Formats

View All CD62L Reagents Request Custom Conjugation
Description Clone Applications
APC anti-human CD62L DREG-56 FC
FITC anti-human CD62L DREG-56 FC
PE anti-human CD62L DREG-56 FC
PE/Cyanine5 anti-human CD62L DREG-56 FC
Purified anti-human CD62L DREG-56 FC,WB,Block
APC/Cyanine7 anti-human CD62L DREG-56 FC
Alexa Fluor® 488 anti-human CD62L DREG-56 FC
Alexa Fluor® 647 anti-human CD62L DREG-56 FC
Alexa Fluor® 700 anti-human CD62L DREG-56 FC
PE/Cyanine7 anti-human CD62L DREG-56 FC
PerCP/Cyanine5.5 anti-human CD62L DREG-56 FC
Pacific Blue™ anti-human CD62L DREG-56 FC
Brilliant Violet 421™ anti-human CD62L DREG-56 FC
Brilliant Violet 785™ anti-human CD62L DREG-56 FC
Brilliant Violet 650™ anti-human CD62L DREG-56 FC
PE/Dazzle™ 594 anti-human CD62L DREG-56 FC
Brilliant Violet 605™ anti-human CD62L DREG-56 FC
Purified anti-human CD62L (Maxpar® Ready) DREG-56 FC,CyTOF®
APC/Fire™ 750 anti-human CD62L DREG-56 FC
Brilliant Violet 510™ anti-human CD62L DREG-56 FC
TotalSeq™-A0147 anti-human CD62L DREG-56 PG
TotalSeq™-B0147 anti-human CD62L DREG-56 PG
TotalSeq™-C0147 anti-human CD62L DREG-56 PG
Ultra-LEAF™ Purified anti-human CD62L DREG-56 FC,Block,WB
Brilliant Violet 711™ anti-human CD62L DREG-56 FC
Spark NIR™ 685 anti-human CD62L DREG-56 FC
TotalSeq™-D0147 anti-human CD62L DREG-56 PG
APC/Fire™ 810 anti-human CD62L DREG-56 FC
FITC anti-human CD62L DREG-56 FC
PE/Dazzle™ 594 anti-human CD62L DREG-56 FC
PerCP/Fire™ 806 anti-human CD62L DREG-56 FC
APC anti-human CD62L DREG-56 FC
GMP FITC anti-human CD62L DREG-56 FC
Go To Top Version: 1    Revision Date: 09.06.2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account