Purified anti-human CD235ab Antibody

Pricing & Availability
Clone
HIR2 (See other available formats)
Regulatory Status
RUO
Workshop
VII 70299
Other Names
Glycophorin A/B, GPA/GPB, GYPA, GYPB
Isotype
Mouse IgG2b, κ
Ave. Rating
Submit a Review
Product Citations
publications
1_HIR2
Human red blood cells stained with CD235a/b PE
  • 1_HIR2
    Human red blood cells stained with CD235a/b PE
  • 2_HIR2_PURE_CD235ab_Antibody_IHC-P_062221.png
    IHC staining of purified anti-human CD235ab antibody (clone HIR2) on formalin-fixed paraffin-embedded human spleen tissue. Following antigen retrieval using 0.1 M Tris-buffered saline with Tween 20 (Cat. No. 925501), the tissue was incubated with 1 µg/mL of the primary antibody overnight at 4°C, followed by incubation with 2.5 µg/mL of Alexa Fluor® 647 goat anti-mouse IgG (green) (Cat. No. 405322) for one hour at room temperature. Nuclei were counterstained with DAPI (blue), and the slide was mounted with ProLong™ Gold Antifade Mountant. The image was captured with a 10x objective. Scale bar: 100 µm
  • 3_HIR2_PURE_CD235ab_Antibody_SB_111623
    SeqIF™ (sequential immunofluorescence) staining on COMET™ of Purified anti-CD235ab (clone HIR2, yellow) on formalin-fixed paraffin-embedded human pancreatic carcinoma at 0.83 µg/mL. Alexa Fluor™ Plus 647 Goat anti-Mouse IgG antibody (Lunaphore, Cat. No. DR647MS) was used as a secondary antibody. Nuclei were counterstained with DAPI (blue). Tissue underwent an all-in-one dewaxing and antigen retrieval preprocessing.
Compare all formats See high resolution SB data...
Cat # Size Price Quantity Check Availability Save
306602 100 µg 82€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

The HIR2 antibody reacts with a common epitope of glycophorin A (CD235a) and glycophorin B (CD235b). Glycophorin A is the major sialoglycoprotein expressed on red blood cell membrane, and erythroid precursors. Glycophorin A shares strong homology with glycophorin B. The HIR2 antibody recognizes human RBCs and erythroid precursors and is useful in erythroid cell development studies. Mature, non-nucleated red blood cells are characteristically glycophorin A positive, but CD45 and CD71 negative.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human
Reported Reactivity
African Green, Baboon
Antibody Type
Monoclonal
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography.
Concentration
0.5 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C.
Application

FC - Quality tested
CyTOF®, IHC-P - Verified
SB - Community verified

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.125 µg per million cells in 100 µL volume. For immunohistochemistry on formalin-fixed paraffin-embedded tissue sections, a concentration range of 1.0 µg/ml is suggested. It is recommended that the reagent be titrated for optimal performance for each application.

Additional Product Notes

For the use of this antibody in spatial biology applications, we have partnered with Lunaphore Technologies for demonstration of our antibodies on the COMET™. The COMET™ platform is an automated, end-to-end spatial biology solution developed for rapid and flexible multiplex tissue profiling. More information on the COMET™ and a complete list of our antibodies that have been demonstrated on the COMET™ can be found here.

Application References

(PubMed link indicates BioLegend citation)
  1. Mason D, et al. Eds. 2002. Leucocyte Typing VII. Oxford University Press. New York.
Product Citations
  1. Arnold DP, et al. 2023. Nat Commun. 14:2884. PubMed
  2. Valet C, et al. 2022. J Clin Invest. 132: . PubMed
  3. Feyaerts D, et al. 2022. Cell Rep Med. 3:100680. PubMed
  4. Azizi E et al. 2018. Cell. 174(5):1293-1308 e36. PubMed
  5. Vivanco Gonzalez N, et al. 2022. STAR Protoc. 3:101280. PubMed
  6. Wastyk HC, et al. 2021. Cell. 184(16):4137-4153.e14. PubMed
  7. Eccles JD, et al. 2020. Cell Rep. 30:351. PubMed
  8. Hartmann FJ, et al. 2019. Cell Rep. 28:819. PubMed
  9. Evrard M et al. 2018. Immunity. 48(2):364-379 . PubMed
  10. Dinh HQ, et al. 2020. Immunity. 53(2):319-334.e6. PubMed
RRID
AB_314620 (BioLegend Cat. No. 306602)

Antigen Details

Structure
Sialoglycoprotein, 20 kD
Distribution

Erythrocytes

Cell Type
Erythrocytes
Biology Area
Immunology
Molecular Family
CD Molecules
Antigen References

1. Mason D, et al. Eds. 2002. Leucocyte Typing VII. Oxford University Press. New York.

Gene ID
2993 View all products for this Gene ID
UniProt
View information about CD235ab on UniProt.org

Related FAQs

If an antibody clone has been previously successfully used in IBEX in one fluorescent format, will other antibody formats work as well?

It’s likely that other fluorophore conjugates to the same antibody clone will also be compatible with IBEX using the same sample fixation procedure. Ultimately a directly conjugated antibody’s utility in fluorescent imaging and IBEX may be specific to the sample and microscope being used in the experiment. Some antibody clone conjugates may perform better than others due to performance differences in non-specific binding, fluorophore brightness, and other biochemical properties unique to that conjugate.

Will antibodies my lab is already using for fluorescent or chromogenic IHC work in IBEX?

Fundamentally, IBEX as a technique that works much in the same way as single antibody panels or single marker IF/IHC. If you’re already successfully using an antibody clone on a sample of interest, it is likely that clone will have utility in IBEX. It is expected some optimization and testing of different antibody fluorophore conjugates will be required to find a suitable format; however, legacy microscopy techniques like chromogenic IHC on fixed or frozen tissue is an excellent place to start looking for useful antibodies.

Are other fluorophores compatible with IBEX?

Over 18 fluorescent formats have been screened for use in IBEX, however, it is likely that other fluorophores are able to be rapidly bleached in IBEX. If a fluorophore format is already suitable for your imaging platform it can be tested for compatibility in IBEX.

The same antibody works in one tissue type but not another. What is happening?

Differences in tissue properties may impact both the ability of an antibody to bind its target specifically and impact the ability of a specific fluorophore conjugate to overcome the background fluorescent signal in a given tissue. Secondary stains, as well as testing multiple fluorescent conjugates of the same clone, may help to troubleshoot challenging targets or tissues. Using a reference control tissue may also give confidence in the specificity of your staining.

How can I be sure the staining I’m seeing in my tissue is real?

In general, best practices for validating an antibody in traditional chromogenic or fluorescent IHC are applicable to IBEX. Please reference the Nature Methods review on antibody based multiplexed imaging for resources on validating antibodies for IBEX.

Go To Top Version: 3    Revision Date: 11/16/2023

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account