Brilliant Violet 650™ anti-mouse CD80 Antibody

Pricing & Availability
Clone
16-10A1 (See other available formats)
Regulatory Status
RUO
Other Names
B7-1, B7, Ly-53
Isotype
Armenian Hamster IgG
Ave. Rating
Submit a Review
Product Citations
publications
16-10A1_BV650_031512
LPS-stimulated (day 3) C57BL/6 mouse splenocytes were stained with CD80 (clone 16-10A1) Brilliant Violet 650™.
  • 16-10A1_BV650_031512
    LPS-stimulated (day 3) C57BL/6 mouse splenocytes were stained with CD80 (clone 16-10A1) Brilliant Violet 650™.
Compare all formats See Brilliant Violet 650™ spectral data
Cat # Size Price Save
104731 125 µL ¥42,190
104732 50 µg ¥49,430
Description

CD80 is a 60 kD highly glycosylated protein. It is a member of the Ig superfamily and is also known as B7-1, B7, and Ly-53. CD80 is constitutively expressed on dendritic cells and monocytes/macrophages, and inducibly expressed on activated B and T cells. The ligation of CD28 on T cells with CD80 and CD86 (B7-2) on antigen presenting cells (such as dendritic cells, macrophages, and B cells) elicits co-stimulation of T cells resulting in enhanced cell activation, proliferation, and cytokine production. CD80 appears to be expressed later in the immune response than CD86. CD80 can also bind to CD152, also known as CTLA-4, to deliver an inhibitory signal to T cells.

Product Details
Technical data sheet

Product Details

Verified Reactivity
Mouse
Reported Reactivity
Dog
Antibody Type
Monoclonal
Host Species
Armenian Hamster
Immunogen
CHO cell line transfected with mouse B7 (CD80)
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA).
Preparation
The antibody was purified by affinity chromatography and conjugated with Brilliant Violet 650™ under optimal conditions.
Concentration
µg sizes: 0.2 mg/mL
µL sizes: lot-specific (to obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.)
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining using the µl size, the suggested use of this reagent is 5 µl per million cells in 100 µl staining volume or 5 µl per 100 µl of whole blood. For flow cytometric staining using the µg size, the suggested use of this reagent is ≤0.5 µg per million cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.

Brilliant Violet 650™ excites at 405 nm and emits at 645 nm. The bandpass filter 660/20 nm is recommended for detection, although filter optimization may be required depending on other fluorophores used. Be sure to verify that your cytometer configuration and software setup are appropriate for detecting this channel. Refer to your instrument manual or manufacturer for support. Brilliant Violet 650™ is a trademark of Sirigen Group Ltd.


Learn more about Brilliant Violet™.

This product is subject to proprietary rights of Sirigen Inc. and is made and sold under license from Sirigen Inc. The purchase of this product conveys to the buyer a non-transferable right to use the purchased product for research purposes only. This product may not be resold or incorporated in any manner into another product for resale. Any use for therapeutics or diagnostics is strictly prohibited. This product is covered by U.S. Patent(s), pending patent applications and foreign equivalents.
Excitation Laser
Violet Laser (405 nm)
Application Notes

Additional reported applications (for the relevant formats) include: immunoprecipitation2, in vitro and in vivo blocking of CTLA-4 Ig to CD80 by blocking costimulation of T cells by activated B cells2-4, and immunohistochemical staining of acetone-fixed frozen sections1,4. The Ultra-LEAF™ purified antibody (Endotoxin < 0.01 EU/µg, Azide-Free, 0.2 µm filtered) is recommended for functional assays (Cat. Nos. 104747-104752).

Application References

(PubMed link indicates BioLegend citation)
  1. Harlan DM, et al. 1994. P. Natl. Acad. Sci. USA 91:3137. (IHC)
  2. Razi-Wolf Z, et al. 1992. P. Natl. Acad. Sci. USA 89:4210. (Block, IP)
  3. Hathcock KS, et al. 1994. J. Exp. Med. 180:631. (Block)
  4. Herold KC, et al. 1997. J. Immunol. 158:984. (Block, IHC)
  5. Ma XT, et al. 2006. Cancer Res. 66:1169.
  6. Andoniou CE, et al. 2005. Nature Immunology 6:1011. (FC)
  7. Lawson BR, et al. 2007. J. Immunol. 178:5366.
  8. Turnquist HR, et al. 2007. J. Immunol. 178:7018.
  9. Misra RS, et al. 2010. J. Exp Med. 207:1775. PubMed
  10. del Rio ML, et al. 2011. Transpl. Int. 24:501. (FC) PubMed
  11. Philipsen L, et al. 2013. Mol Cell Proteomics. 12:2551. PubMed
Product Citations
  1. Hao H, et al. 2023. Nat Biomed Eng. . PubMed
  2. Tordesillas L, et al. 2018. Nat Commun. 9:5238. PubMed
  3. Mathew NR, et al. 2021. Cell Reports. 35(12):109286. PubMed
  4. Jeong SH, et al. 2021. Nat Commun. 12:4405. PubMed
  5. Naing A et al. 2019. Cell reports. 26(5):1242-1257 . PubMed
  6. Hossain DMS, et al. 2018. J Clin Invest. 128:644. PubMed
  7. Dobosz E, et al. 2021. Dis Model Mech. :14. PubMed
  8. Tacconi C, et al. 2021. Cell Reports. 35(2):108993. PubMed
  9. Cosentino K, et al. 2022. Mol Cell. 82:933. PubMed
  10. Pennock ND, et al. 2018. J Immunother Cancer. 0.318055556. PubMed
  11. Zhang Q, et al. 2021. Front Cell Dev Biol. 9:655552. PubMed
  12. Gomez S, et al. 2022. J Immunother Cancer. 10:. PubMed
  13. Zhang Q, et al. 2022. Commun Biol. 5:544. PubMed
  14. Lu X, et al. 2019. Circ Res. 125:1055. PubMed
  15. Moufarrij S, et al. 2020. Sci Rep. 10:3470. PubMed
  16. Singhal P, et al. 2016. Proc Natl Acad Sci U S A. 113: 122 - 127. PubMed
  17. Hering L, et al. 2020. Front Immunol. 1.747222222. PubMed
  18. Jones D, et al. 2015. J Immunol. 195: 4753 - 4759. PubMed
RRID
AB_11147759 (BioLegend Cat. No. 104731)
AB_11147759 (BioLegend Cat. No. 104732)

Antigen Details

Structure
Ig superfamily, 60 kD
Distribution

Macrophages, activated B cells and T cells, dendritic cells

Function
T cell costimulation
Ligand/Receptor
CD28 (stimulatory), CD152(CTLA4) (inhibitory)
Cell Type
B cells, Dendritic cells, Macrophages, T cells, Tregs
Biology Area
Cell Biology, Costimulatory Molecules, Immunology, Neuroscience, Neuroscience Cell Markers
Molecular Family
CD Molecules, Immune Checkpoint Receptors
Antigen References

1. Barclay AN, et al. 1997. The Leukocyte Antigen FactsBook Academic Press.
2. Linsley PS, et al. 1991. J. Exp. Med. 174:561.
3. Salomon B, et al. 2001. Annu. Rev. Immunol. 19:225.

Gene ID
12519 View all products for this Gene ID
UniProt
View information about CD80 on UniProt.org

Related FAQs

There are no FAQs for this product.
Go To Top Version: 3    Revision Date: 11/15/2013

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account