Brilliant Violet 421™ anti-human CD11c Antibody

Pricing & Availability
Clone
3.9 (See other available formats)
Regulatory Status
RUO
Workshop
III NL707
Other Names
Integrin αX subunit, CR4, p150, ITGAX
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
3.9_BV421_061711
Human peripheral blood granulocytes were stained with CD11c (clone 3.9) Brilliant Violet 421™ (filled histogram) or mouse IgG1, κ Brilliant Violet 421™ isotype control (open histogram).
  • 3.9_BV421_061711
    Human peripheral blood granulocytes were stained with CD11c (clone 3.9) Brilliant Violet 421™ (filled histogram) or mouse IgG1, κ Brilliant Violet 421™ isotype control (open histogram).
Compare all formats See Brilliant Violet 421™ spectral data
Cat # Size Price Quantity Check Availability Save
301627 25 tests 146€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
301628 100 tests 308€
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD11c is a 145-150 kD type I transmembrane glycoprotein also known as integrin αX and CR4. CD11c non-covalently associates with integrin β2 (CD18) and is expressed on monocytes/macrophages, dendritic cells, granulocytes, NK cells, and subsets of T and B cells. CD11c has been reported to play a role in adhesion and CTL killing through its interactions with fibrinogen, CD54, and iC3b.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Human, Cynomolgus, Rhesus
Reported Reactivity
African Green, Baboon, Chimpanzee, Squirrel Monkey
Antibody Type
Monoclonal
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and BSA (origin USA).
Preparation
The antibody was purified by affinity chromatography and conjugated with Brilliant Violet 421™ under optimal conditions.
Concentration
Lot-specific (to obtain lot-specific concentration and expiration, please enter the lot number in our Certificate of Analysis online tool.)
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is 5 µl per million cells in 100 µl staining volume or 5 µl per 100 µl of whole blood.

Brilliant Violet 421™ excites at 405 nm and emits at 421 nm. The standard bandpass filter 450/50 nm is recommended for detection. Brilliant Violet 421™ is a trademark of Sirigen Group Ltd.


Learn more about Brilliant Violet™.

This product is subject to proprietary rights of Sirigen Inc. and is made and sold under license from Sirigen Inc. The purchase of this product conveys to the buyer a non-transferable right to use the purchased product for research purposes only. This product may not be resold or incorporated in any manner into another product for resale. Any use for therapeutics or diagnostics is strictly prohibited. This product is covered by U.S. Patent(s), pending patent applications and foreign equivalents.
Excitation Laser
Violet Laser (405 nm)
Application Notes

Clone 3.9 preferentially binds the activated form of CD11c, is specific for the I domain of CD11c, and is able to partially block the binding of CD11c and ICAM-4. 3.9 binding is divalent cation dependent12. While analyzing blood, it is best to use heparin as the anti-coagulant and not EDTA. Since the ability of clone 3.9 to bind to its target is divalent cation dependent, the usage of EDTA as an anti-coagulant may be detrimental to staining due to its chelating properties.

Additional reported applications (for the relevant formats) include: immunohistochemical staining of acetone-fixed frozen tissue sections4, and functional assays5,6. The LEAF™ purified antibody (Endotoxin <0.1 EU/μg, Azide-Free, 0.2 μm filtered) is recommended for functional assays (Cat. No. 301616). For highly sensitive assays, we recommend Ultra-LEAF™ purified antibody (Cat. No. 301632) with a lower endotoxin limit than standard LEAF™ purified antibodies (Endotoxin <0.01 EU/µg).

Application References
  1. Schlossman S, et al. Eds. 1995. Leucocyte Typing V. Oxford University Press. New York.
  2. Knapp W, et al. 1989. Leucocyte Typing IV Oxford University Press. New York.
  3. McMichael A, et al. Eds. 1987. Leucocyte Typing III Oxford University Press. New York.
  4. Vainer B, et al. 2000. Am. J. Surg. Pathol. 24:1115. (IHC)
  5. Ottonello L, et al. 1999. Blood 93:3505.
  6. Metelitsa LS, et al. 2002. Blood 99:4166.
  7. Sadhu C, et al. 2007. J. Leukoc. Biol. doi:10.1189/jlb.1106680. PubMed
  8. Ihanus E, et al. 2007. Blood 109:802-810.
  9. Gurer C, et al. 2008. Blood 112:1231. PubMed
  10. Asai A, et al. 2009. J. Lipid Res. 50:95. PubMed
  11. Yoshino N, et al. 2000. Exp. Anim. (Tokyo) 49:97. (FC)
  12. Sadhu C, et al. 2008. J. Immunoass. Immunoch. 29:42. (FC)
Product Citations
  1. Porbahaie M, et al. 2023. PLoS One. 18:e0279626. PubMed
  2. Arce Vargas F et al. 2018. Cancer cell. 33(4):649-663 . PubMed
  3. Dudley D, et al. 2016. Nat Commun. 7:12204. PubMed
  4. Casasola-LaMacchia A, et al. 2021. Sci Rep. 11:1028. PubMed
  5. Aliota M, et al. 2016. PLoS Negl Trop Dis. 10:e0005168. PubMed
  6. Zhang X, et al. 2021. Front Immunol. 12:680068. PubMed
  7. Jin Y et al. 2019. Nature communications. 10(1):391 . PubMed
  8. Snell LM, et al. 2018. Immunity. 49:678. PubMed
  9. Freeman A, et al. 2014. PLoS One. 9:110928. PubMed
  10. Webb K et al. 2018. Frontiers in immunology. 2.574305556 . PubMed
  11. Schielke L, et al. 2022. Front Immunol. 13:916701. PubMed
RRID
AB_11203895 (BioLegend Cat. No. 301627)
AB_11203895 (BioLegend Cat. No. 301628)

Antigen Details

Structure
Integrin, type I transmembrane glycoprotein, associates with integrin β2 (CD18), 145-150 kD
Distribution

Myeloid, dendritic cells, NK cells, B cells and T cell subsets

Function
Adhesion, CTL killing
Ligand/Receptor
CD54, fibrinogen, iC3b, ICAM-1, ICAM-4
Cell Type
B cells, Dendritic cells, Neutrophils, NK cells, T cells, Tregs
Biology Area
Cell Adhesion, Cell Biology, Costimulatory Molecules, Immunology, Innate Immunity, Neuroscience, Neuroscience Cell Markers
Molecular Family
Adhesion Molecules, CD Molecules
Antigen References

1. Petty H. 1996. Immunol. Today 17:209.
2. Springer T. 1994. Cell 76:301.
3. Ihanus E, et al. 2007. Blood 109:802-810.

Gene ID
3687 View all products for this Gene ID
Specificity (DOES NOT SHOW ON TDS):
CD11c
Specificity Alt (DOES NOT SHOW ON TDS):
CD11c
App Abbreviation (DOES NOT SHOW ON TDS):
FC
UniProt
View information about CD11c on UniProt.org

Related FAQs

What is the F/P ratio range of our BV421™ format antibody reagents?

It is lot-specific. On average it ranges between 2-4.

Go To Top Version: 2    Revision Date: 04-23-2014

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account