- Clone
- MPC-11 (See other available formats)
- Regulatory Status
- RUO
- Isotype
- Mouse IgG2b, κ
- Barcode Sequence
- ATATGTATCACGCGA
- Ave. Rating
- Submit a Review
- Product Citations
- publications
Cat # | Size | Price | Quantity Check Availability | Save | ||
---|---|---|---|---|---|---|
400385 | 10 µg | 296€ |
The MPC-11 immunoglobulin has unknown specificity. This antibody was chosen as an isotype control after screening on a variety of resting, activated, live, and fixed mouse, rat and human tissues.
Product DetailsProduct Details
- Antibody Type
- Monoclonal
- Host Species
- Mouse
- Formulation
- Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide and EDTA
- Preparation
- The antibody was purified by chromatography and conjugated with TotalSeq™-Bn oligomer under optimal conditions.
- Concentration
- 0.5 mg/mL
- Storage & Handling
- The antibody solution should be stored undiluted between 2°C and 8°C. Do not freeze.
- Application
-
SB - Quality tested
- Recommended Usage
-
Each lot of this antibody is quality control tested by immunofluorescent staining in formalin-fixed, paraffin-embedded (FFPE) lymphoid tissue, and the oligomer sequence is confirmed by sequencing. TotalSeq™-Bn antibodies are compatible with the 10x Visium CytAssist Gene and Protein Expression Assay.
To maximize performance, it is strongly recommended that the reagent be titrated for each application, and that you centrifuge the antibody dilution at 14,000xg at 2 − 8°C for 10 minutes before use. Carefully pipette out the liquid avoiding the bottom of the tube when handling. To determine and optimize dilutions for the addition of Totalseq™-Bn antibodies into pre-designed antibody panels, refer to 10x Genomics Custom Add-on Antibody Optimization guide.
Buyer is solely responsible for determining whether Buyer has all intellectual property rights that are necessary for Buyer's intended uses of the BioLegend TotalSeq™ products. For example, for any technology platform Buyer uses with TotalSeq™, it is Buyer's sole responsibility to determine whether it has all necessary third party intellectual property rights to use that platform and TotalSeq™ with that platform. - Application Notes
-
Additional reported applications (for the relevant formats) include: Intracellular Flow Cytometry (ICFC), Immunocytochemistry (ICC), Immunohistochemistry (IHC), Immunoprecipitation (IP), Western Blotting (WB), Functional Assay (FA).
- Additional Product Notes
-
TotalSeq™-Bn reagents are designed to profile protein levels following an optimized protocol in spatial transcriptomics. Compatible spatial biology devices (e.g. Imaging System, 10x Genomics Visium Spatial CytAssist Gene and Protein Expression instruments and reagents) and sequencer (e.g. Illumina analyzers) are required. TotalSeq™-B reagents are not compatible with the 10x Genomics Visium system. The complete barcode sequence may be provided upon request. Please contact technical support for more information, or visit TotalSeq™-Bn Reagents for 10x Genomics Visium CytAssist Gene and Protein Assay.
- Application References
- RRID
-
AB_3097172 (BioLegend Cat. No. 400385)
Antigen Details
- Gene ID
- NA
Related Pages & Pathways
Pages
Related FAQs
- If an antibody clone has been previously successfully used in IBEX in one fluorescent format, will other antibody formats work as well?
-
It’s likely that other fluorophore conjugates to the same antibody clone will also be compatible with IBEX using the same sample fixation procedure. Ultimately a directly conjugated antibody’s utility in fluorescent imaging and IBEX may be specific to the sample and microscope being used in the experiment. Some antibody clone conjugates may perform better than others due to performance differences in non-specific binding, fluorophore brightness, and other biochemical properties unique to that conjugate.
- Will antibodies my lab is already using for fluorescent or chromogenic IHC work in IBEX?
-
Fundamentally, IBEX as a technique that works much in the same way as single antibody panels or single marker IF/IHC. If you’re already successfully using an antibody clone on a sample of interest, it is likely that clone will have utility in IBEX. It is expected some optimization and testing of different antibody fluorophore conjugates will be required to find a suitable format; however, legacy microscopy techniques like chromogenic IHC on fixed or frozen tissue is an excellent place to start looking for useful antibodies.
- Are other fluorophores compatible with IBEX?
-
Over 18 fluorescent formats have been screened for use in IBEX, however, it is likely that other fluorophores are able to be rapidly bleached in IBEX. If a fluorophore format is already suitable for your imaging platform it can be tested for compatibility in IBEX.
- The same antibody works in one tissue type but not another. What is happening?
-
Differences in tissue properties may impact both the ability of an antibody to bind its target specifically and impact the ability of a specific fluorophore conjugate to overcome the background fluorescent signal in a given tissue. Secondary stains, as well as testing multiple fluorescent conjugates of the same clone, may help to troubleshoot challenging targets or tissues. Using a reference control tissue may also give confidence in the specificity of your staining.
- How can I be sure the staining I’m seeing in my tissue is real?
-
In general, best practices for validating an antibody in traditional chromogenic or fluorescent IHC are applicable to IBEX. Please reference the Nature Methods review on antibody based multiplexed imaging for resources on validating antibodies for IBEX.
Other Formats
View All Reagents Request Custom ConjugationCompare Data Across All Formats
This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.
-
APC Mouse IgG2b, κ Isotype Ctrl
-
Biotin Mouse IgG2b, κ Isotype Ctrl
-
FITC Mouse IgG2b, κ Isotype Ctrl
-
PE Mouse IgG2b, κ Isotype Ctrl
-
PE/Cyanine5 Mouse IgG2b, κ Isotype Ctrl
-
Purified Mouse IgG2b, κ Isotype Ctrl
-
APC/Cyanine7 Mouse IgG2b, κ Isotype Ctrl
-
PE/Cyanine7 Mouse IgG2b, κ Isotype Ctrl
-
Alexa Fluor® 647 Mouse IgG2b, κ Isotype Ctrl
-
Alexa Fluor® 488 Mouse IgG2b, κ Isotype Ctrl
-
Pacific Blue™ Mouse IgG2b, κ Isotype Ctrl
-
Alexa Fluor® 700 Mouse IgG2b, κ Isotype Ctrl
-
PerCP Mouse IgG2b, κ Isotype Ctrl
-
PerCP/Cyanine5.5 Mouse IgG2b, κ Isotype Ctrl
-
Brilliant Violet 421™ Mouse IgG2b, κ Isotype Ctrl
-
Brilliant Violet 570™ Mouse IgG2b, κ Isotype Ctrl
-
Brilliant Violet 510™ Mouse IgG2b, κ Isotype Ctrl
-
Ultra-LEAF™ Purified Mouse IgG2b, κ Isotype Ctrl
-
Brilliant Violet 605™ Mouse IgG2b, κ Isotype Ctrl
-
Brilliant Violet 650™ Mouse IgG2b, κ Isotype Ctrl
-
Brilliant Violet 711™ Mouse IgG2b, κ Isotype Ctrl
-
Brilliant Violet 785™ Mouse IgG2b, κ Isotype Ctrl
-
PE/Dazzle™ 594 Mouse IgG2b, κ Isotype Ctrl
-
Alexa Fluor® 594 Mouse IgG2b, κ Isotype Ctrl
-
APC/Fire™ 750 Mouse IgG2b, κ Isotype Ctrl
-
GoInVivo™ Purified Mouse IgG2b, κ Isotype Ctrl
-
FITC Mouse IgG2b, κ Isotype Ctrl
-
Pacific Blue™ Mouse IgG2b, κ Isotype Ctrl
-
APC Mouse IgG2b, κ Isotype Ctrl
-
TotalSeq™-A0092 Mouse IgG2b, κ isotype Ctrl
-
PE/Cyanine7 Mouse IgG2b, κ Isotype Ctrl
-
TotalSeq™-B0092 Mouse IgG2b, κ isotype Ctrl
-
TotalSeq™-C0092 Mouse IgG2b, κ isotype Ctrl
-
PerCP/Cyanine5.5 Mouse IgG2b, κ Isotype Ctrl
-
TotalSeq™-D0092 Mouse IgG2b, κ Isotype Ctrl
-
GMP APC Mouse IgG2b, κ Isotype Ctrl
-
GMP FITC Mouse IgG2b, κ Isotype Ctrl
-
GMP Pacific Blue™ Mouse IgG2b, κ Isotype Ctrl
-
GMP PerCP/Cyanine5.5 Mouse IgG2b, κ Isotype Ctrl
-
Brilliant Violet 750™ Mouse IgG2b, κ Isotype Ctrl
-
Spark NIR 685™ Mouse IgG2b, κ Isotype Ctrl
-
PE/Fire™ 810 Mouse IgG2b, κ Isotype Ctrl
-
TotalSeq™-Bn0092 Mouse IgG2b, κ Isotype Ctrl
-
PE/Fire™ 700 Mouse IgG2b, κ Isotype Ctrl
-
KIRAVIA Blue 520™ Mouse IgG2b, κ Isotype Ctrl
-
PE/Fire™ 640 Mouse IgG2b, κ Isotype Ctrl
-
GMP PE/Cyanine7 Mouse IgG2b, κ Isotype Ctrl
-
APC/Fire™ 810 Mouse IgG2b, κ Isotype Ctrl
-
Spark YG™ 570 Mouse IgG2b, κ Isotype Ctrl
-
PerCP/Fire™ 806 Mouse IgG2b, κ Isotype Ctrl
-
Spark Red™ 718 Mouse IgG2b, κ Isotype Ctrl
-
Spark Blue™ 515 Mouse IgG2b, κ Isotype Ctrl
-
PerCP/Fire™ 780 Mouse IgG2b, κ Isotype Ctrl
-
PE/Fire™ 744 Mouse IgG2b, κ Isotype Ctrl
-
Spark PLUS UV395™ Mouse IgG2b, κ Isotype Ctrl
-
TotalSeq™-B1473 Mouse IgG2b, κ Isotype Ctrl
Follow Us