Spark Red™ 718 anti-human CD11a (Flexi-Fluor™) Antibody

Pricing & Availability
Clone
HI111 (See other available formats)
Regulatory Status
RUO
Workshop
IV N231
Other Names
LFA-1α chain, Integrin αL subunit, αL Integrin, ITGAL
Isotype
Mouse IgG1, κ
Ave. Rating
Submit a Review
Product Citations
publications
Cat # Size Price Quantity Save
285076 50 µg $375
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

CD11a is a 170-180 kD type I transmembrane glycoprotein also known as LFA-1α chain and integrin αL subunit. CD11a non-covalently associates with integrin β2 (CD18) to form LFA-1. It is expressed on all leukocytes, including B and T lymphocytes, monocytes, macrophages, neutrophils, basophils and eosinophils. It is absent on non-hematopoietic tissues and platelets. CD11a plays a central role in leukocyte cell-cell interactions and is important in lymphocyte costimulation. CD11a/CD18 binds to ICAM-1 (CD54), ICAM-2 (CD102), and ICAM-3 (CD50).

Product Details
Technical data sheet

Product Details

Verified Reactivity
Human
Reported Reactivity
African Green, Baboon, Cow, Capuchin monkey, Chimpanzee, Cynomolgus, Dog, Horse, Rabbit, Sheep
Antibody Type
Monoclonal
Host Species
Mouse
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide
Preparation
The antibody was purified by affinity chromatography and conjugated with Spark Red™ 718 under optimal conditions.
Concentration
0.2 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC

Recommended Usage
Flexi-Fluors™ are provided at a standard 0.2 mg/mL concentration. We recommend titrating this reagent to determine the optimal concentration for each application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL. We recommend testing a range of concentrations starting from 10 µg/mL.

For example, make five 1:1 serial dilutions of the 0.2 mg/mL antibody. Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/mL) to test six concentrations -- 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration.
Excitation Laser
Red Laser (633 nm)
Application Notes

Clone HI111 epitope maps to the top region of the I domain that is close to the putative ligand-binding site surrounding the MIDAS (metal ion-dependent adhesion site). HI111 is specific for the closed confirmation of the integrin8. Additional reported applications (for the relevant formats) include: immunohistochemical staining of acetone-fixed frozen sections, Western blotting2, and blocking of cell-cell interaction and inhibition the binding of ICAM-14. This clone was tested in-house and does not work on formalin fixed paraffin-embedded (FFPE) tissue. The Ultra-LEAF™ purified antibody (Endotoxin < 0.01 EU/µg, Azide-Free, 0.2 µm filtered) is recommended for functional assays (Cat. No. 301233 & 301234).

Additional Product Notes

For more information about Flexi-Fluors™, visit our Flexi-Fluor™ page and review FAQs associated with this product line.

Application References

(PubMed link indicates BioLegend citation)
  1. Knapp W, et al. 1989. Leucocyte Typing IV. Oxford University Press New York.
  2. Leite F, et al. 2002. Infec. Immun. 70:4336.
  3. Jiang Y, et al. 2005. Clin. Hemorheol. Microcircul. 32:261.
  4. BTchard D, et al. 2001. J. Immunol. 167:3099.
  5. Sithu SD, et al. 2007. J. Biol. Chem. doi:10.1074/jbc.M611273200.
  6. Choi EY, et al. 2008. Blood 111:3607. PubMed
  7. Yoshino N, et al. 2000. Exp. Anim. (Tokyo) 49:97. (FC)
  8. Ma Q, et al. 2002. J. Biol. Chem. 277:10638.
RRID
AB_3106333 (BioLegend Cat. No. 285076)

Antigen Details

Structure
Integrin, type I transmembrane glycoprotein, noncovalently linked with integrin β2 (CD18) forms LFA-1, 170-180 kD
Distribution

Leukocytes

Function
Adhesion, costimulation
Ligand/Receptor
ICAM-1(CD54), ICAM-2(CD102), ICAM-3(CD50)
Cell Type
Leukocytes, Tregs
Biology Area
Cell Adhesion, Cell Biology, Costimulatory Molecules, Immunology, Innate Immunity, Neuroinflammation, Neuroscience
Molecular Family
Adhesion Molecules, CD Molecules
Antigen References

1. Lub M, et al. 1995. Immunol. Today 16:479.
2. Parsons J. 1996. Curr. Opin. Cell Biol. 8:146.

Gene ID
3683 View all products for this Gene ID
UniProt
View information about CD11a on UniProt.org

Related FAQs

What are Flexi-Fluors?

Flexi-Fluors are rapidly made-to-order conjugated antibodies. The technology, manufacturing processes, and specifications used to create Flexi-Fluors are the same as our regular catalog products. However, the optimal concentration and performance of each Flexi-Fluor must be determined by the customer. 

How quickly will I receive my order?

We aim to ship Flexi-Fluors within 2-3 weeks of receipt of your order. However, depending on your location, shipping times may vary. 

How are Flexi-Fluors different from regular catalog products?

Flexi-Fluors are made on demand, specifically for you. Flexi-Fluors are manufactured using the same high-quality standards, and specifications as other catalog products. For faster delivery, Flexi-Fluors are not tested by flow cytometry to determine optimal concentrations or evaluate performance. This testing needs to be performed by the customer.

How do I determine the optimal concentration for using my Flexi-Fluor? How should I titrate my antibody?

Flexi-Fluors are provided at a standard 0.2 mg/mL concentration. We recommend that you titrate your antibody to determine the optimal concentration to use for your application. For many flow cytometry applications, conjugated antibodies perform well at concentrations ranging from 0.03 to 1.0 µg per million cells in 100 µL volume. We recommend that you test a range of concentrations starting from 10 µg/mL. 

 

For example, make five 1:1 serial dilutions of your 0.2 mg/mL antibody.  Add 5 µL of each dilution (including the undiluted antibody) to 100 µL of cells (at 107 cells/ml) to test six concentrations - 1.0, 0.5, 0.25, 0.125, 0.06, and 0.03 µg per million cells in 100 µL volume. Compare staining patterns or create a titration curve using the MFI or staining index to determine the optimal concentration. 

I can’t find the antibody-dye combination that I need. When will it be available?

We continuously update our catalog, introducing scores of new products every month. Please get in touch with our Technical Service team for an update on new products or recommendations for suitable alternatives to complete your panel. Or contact Custom Solutions to inquire about our affordable custom conjugation services. 

I need help to validate the performance of my Flexi-Fluor. Who should I contact?

Please get in touch with Technical Service for assistance. 

Can I order more than 50 μg of a Flexi-Fluor?

Yes, you can order multiple vials of the same Flexi-Fluor products.  We cannot guarantee, however, that these vials will be bottled from the same lot. For bulk single-lot orders, contact our Custom Solutions team.

What is the expiration date of my Flexi-Fluor?

Expiration dates can be found on the vial label or by using our CoA lookup tool

Go To Top Version: 1    Revision Date: 02/07/2024

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login/Register
Remember me
Forgot your password? Reset Password
Request an Account