Alexa Fluor® 488 Donkey anti-rabbit IgG (minimal x-reactivity) Antibody

Pricing & Availability
Clone
Poly4064 (See other available formats)
Regulatory Status
RUO
Isotype
Donkey Polyclonal Ig
Poly4064_AF488_IgG_ANtibody_FC_022014.jpg
C57BL/6 splenocytes were stained with NK-1.1 Brilliant Violet 421™ and purified rabbit anti-Asialo-GM1, followed by donkey anti-rabbit IgG (clone Poly4064) Alexa Fluor® 488 (top image).
  • Poly4064_AF488_IgG_ANtibody_FC_022014.jpg
    C57BL/6 splenocytes were stained with NK-1.1 Brilliant Violet 421™ and purified rabbit anti-Asialo-GM1, followed by donkey anti-rabbit IgG (clone Poly4064) Alexa Fluor® 488 (top image).
Compare all formats See Alexa Fluor® 488 spectral data
Cat # Size Price Quantity Check Availability
406416 100 µg $141.00
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

This polyclonal donkey anti-rabbit IgG antibody reacts with the heavy chains of rabbit IgG and with the light chains common to most rabbit immunoglobulins. No cross-reactivity has been detected against non-immunoglobulin serum proteins. This antibody has been solid-phase absorbed to ensure minimal cross-reaction with rat, human, bovine, horse, and mouse immunoglobulins, but it may cross-react with other subclasses of rabbit immunoglobulins.

Technical data sheet

Product Details

Verified Reactivity
Rabbit
Antibody Type
Polyclonal
Host Species
Donkey
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography and conjugated with Alexa Fluor® 488 under optimal conditions.
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤0.5 µg per million cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.


Alexa Fluor® and Pacific Blue™ are trademarks of Life Technologies Corporation.

View full statement regarding label licenses
Excitation Laser
Blue Laser (488 nm)
Application Notes

This conjugated polyclonal donkey anti-rabbit IgG antibody is useful for immunofluorescent staining for flow cytometry, or microscopy.

Product Citations
  1. Li H, et al. 2022. Sci Adv. 8:eabm4006. PubMed
  2. Tan J, et al. 2021. iScience. 24(8):102835. PubMed
  3. Liu J, et al. 2019. Mol Med Rep. 20:33. PubMed
  4. Deisher A, et al. 2022. STAR Protoc. 3:101663. PubMed
  5. Tzeng HR, et al. 2020. Neurotherapeutics. 18:569. PubMed
  6. Delbridge ARD, et al. 2021. Front Cell Neurosci. 14:592005. PubMed
  7. Procházková P, et al. 2019. Front Immunol. 10:1277. PubMed
  8. Bergeron S, et al. 2021. British Journal of Pharmacology. 178(7):1705-1721. PubMed
  9. Britschgi A, et al. 2017. Nature. 541:541-545. PubMed
  10. Song J,et al. 2017. Arch Virol.. 10.1007/s00705-017-3592-x. PubMed
  11. Catapano M, et al. 2020. J Invest Dermatol. 140:816. PubMed
  12. McCullough LD, et al. 2021. J Clin Invest. 131:. PubMed
  13. Chi A, et al. 2022. Front Endocrinol (Lausanne). 13:871548. PubMed
  14. Singh A, et al. 2020. Mol Oncol. 1.901388889. PubMed
  15. Burns JC, et al. 2020. eLife. 9:00. PubMed
  16. Carestia A, et al. 2019. Cell Rep. 28:896. PubMed
  17. Ahmed Ali A, et al. 2016. Sci Rep. 6:36650. PubMed
  18. Sung P, et al. 2014. J Virol. 88:9233. PubMed
  19. Singh KS, et al. 2021. Nature. 589:597. PubMed
  20. Nie Y, et al. 2021. Virol Sin. 36:692. PubMed
  21. Scharenberg SG, et al. 2020. Nat Commun. 2.76875. PubMed
RRID
AB_2563203 (BioLegend Cat. No. 406416)
Go To Top Version: 3    Revision Date: 02/09/2017

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.