Alexa Fluor® 700 anti-mouse CD326 (Ep-CAM) Antibody

Pricing & Availability
Clone
G8.8 (See other available formats)
Regulatory Status
RUO
Other Names
CD326, EGP40, MIC18, TROP1, KSA
Isotype
Rat IgG2a, κ
Ave. Rating
Submit a Review
Product Citations
publications
G8-8_A700_CD326_Antibody_042519
TE-71 (mouse thymic epithelial stromal cell line) was stained with CD326 (clone G8.8) Alexa Fluor® 700 (filled histogram) or Rat IgG2a, κ Alexa Fluor® 700 isotype control (empty histogram).
  • G8-8_A700_CD326_Antibody_042519
    TE-71 (mouse thymic epithelial stromal cell line) was stained with CD326 (clone G8.8) Alexa Fluor® 700 (filled histogram) or Rat IgG2a, κ Alexa Fluor® 700 isotype control (empty histogram).
Compare all formats See Alexa Fluor® 700 spectral data
Cat # Size Price Quantity Check Availability Save
118239 25 µg 147 CHF
Check Availability


Need larger quantities of this item?
Request Bulk Quote
118240 100 µg 347 CHF
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

EpCAM (CD326) mediates calcium-independent homophilic cell to cell adhesion. It may also function as a growth factor receptor. It is thought to be involved in maintaining cells in position during proliferation. Expression of EpCAM seems to correlate inversely with the level of E-cadherin (CD324). EpCAM is considered important in tumor biology.

Product Details
Technical Data Sheet (pdf)

Product Details

Verified Reactivity
Mouse
Antibody Type
Monoclonal
Host Species
Rat
Immunogen
TE-71 thymic epithelial cell line
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography and conjugated with Alexa Fluor® 700 under optimal conditions.
Concentration
0.5 mg/ml
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

FC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunofluorescent staining with flow cytometric analysis. For flow cytometric staining, the suggested use of this reagent is ≤ 0.5 µg per million cells in 100 µl volume. It is recommended that the reagent be titrated for optimal performance for each application.

* Alexa Fluor® 700 has a maximum emission of 719 nm when it is excited at 633 nm / 635 nm. Prior to using Alexa Fluor® 700 conjugate for flow cytometric analysis, please verify your flow cytometer's capability of exciting and detecting the fluorochrome.


Alexa Fluor® and Pacific Blue™ are trademarks of Life Technologies Corporation.

View full statement regarding label licenses
Excitation Laser
Red Laser (633 nm)
Application Notes

Additional reported applications for clone G8.8 (for the relevant formats) include: immunohistochemistry of frozen sections: acetone fixed1, with or without OCT embedding2,4, and spatial biology (IBEX)13,14.

Application References

(PubMed link indicates BioLegend citation)
  1. Farr A, et al. 1991. J. Histochem. Cytochem. 39:645. (FC, IHC)
  2. Dooley J, et al. 2005. J. Immunol. 175:4331. (FC, IHC)
  3. Hinterberger M, et. al. 2010. Nat. Immunol. 11:512. (FC) PubMed
  4. Gracz AD, et al. 2010. Am J. Physiol Gastrointest Liver Physiol. 298:590. (IHC) PubMed
  5. Nudel I, et al. 2011. J. Immunol. 186:891. PubMed
  6. Morimoto H, et al. 2012. Biol Reprod. 86:148. PubMed
  7. Ishii K, et al. 2012. Development. 139:1734. PubMed
  8. Takehashi M, et al. 2012. Biol Reprod. 86:178. PubMed
  9. Murakami R, et al. 2013. PLoS One. 8:73270. PubMed
  10. Taguchi K, et al. 2014. Mol Cell Biol. 34:900. PubMed
  11. Hirokawa Y, et al. 2014. Am J Physiol Gastrointerest Liver Physiol. 306:547. PubMed
  12. Ding X, et al. 2015. Cancer Res. 75:330. PubMed
  13. Radtke AJ, et al. 2020. Proc Natl Acad Sci U S A. 117:33455-65. (SB) PubMed
  14. Radtke AJ, et al. 2022. Nat Protoc. 17:378-401. (SB) PubMed
Product Citations
  1. Mohamed GA, et al. 2023. Breast Cancer Res. 25:23. PubMed
RRID
AB_2810354 (BioLegend Cat. No. 118239)
AB_2810354 (BioLegend Cat. No. 118240)

Antigen Details

Structure
40 kD single-pass type 1 glycoprotein. 293 amino acids, with a 21 aa signal peptide, a 246 aa extracellular domain, a 21 aa transmembrane domain, and a 26 aa cytoplasmic domain. The extracellular domain contains two epidermal growth factor-like repeats.
Distribution

Expressed on majority of epithelial cell membranes with the exception of adult squamous cells of the skin and a few specific epithelial cell types.

Function
Mediates calcium-independent homophilic cell-cell adhesion.
Interaction
CD326 displays hemophilic binding.
Ligand/Receptor
CD305 (LAIR-1), CD306 (LAIR-2), and Ep-CAM.
Cell Type
Embryonic Stem Cells, Epithelial cells
Biology Area
Immunology, Stem Cells
Molecular Family
Adhesion Molecules, CD Molecules
Antigen References

1. Borkowski TA, et al. 1996. Eur. J. Immunol. 26:110.
2. Bergsagel PL, et al. 1992. J. Immunol. 148:590.

Gene ID
17075 View all products for this Gene ID
UniProt
View information about CD326 on UniProt.org

Related FAQs

There are no FAQs for this product.

Other Formats

View All CD326 Reagents Request Custom Conjugation
Description Clone Applications
APC anti-mouse CD326 (Ep-CAM) G8.8 FC
Purified anti-mouse CD326 (Ep-CAM) G8.8 FC,IHC-F,ICC
Biotin anti-mouse CD326 (Ep-CAM) G8.8 FC
PE anti-mouse CD326 (Ep-CAM) G8.8 FC
FITC anti-mouse CD326 (Ep-CAM) G8.8 FC
Alexa Fluor® 488 anti-mouse CD326 (Ep-CAM) G8.8 FC,IHC-F,3D IHC
Alexa Fluor® 647 anti-mouse CD326 (Ep-CAM) G8.8 FC,IHC-F,3D IHC,SB
PE/Cyanine7 anti-mouse CD326 (Ep-CAM) G8.8 FC
APC/Cyanine7 anti-mouse CD326 (Ep-CAM) G8.8 FC
PerCP/Cyanine5.5 anti-mouse CD326 (Ep-CAM) G8.8 FC
Alexa Fluor® 594 anti-mouse CD326 (Ep-CAM) G8.8 ICC,IHC-F,3D IHC
Brilliant Violet 421™ anti-mouse CD326 (Ep-CAM) G8.8 FC
Brilliant Violet 605™ anti-mouse CD326 (Ep-CAM) G8.8 FC
Purified anti-mouse CD326 (Ep-CAM) (Maxpar® Ready) G8.8 FC,CyTOF®
APC/Fire™ 750 anti-mouse CD326 (Ep-CAM) G8.8 FC
Brilliant Violet 711™ anti-mouse CD326 (Ep-CAM) G8.8 FC
Brilliant Violet 510™ anti-mouse CD326 (Ep-CAM) G8.8 FC
PE/Dazzle™ 594 anti-mouse CD326 (Ep-CAM) G8.8 FC
TotalSeq™-A0449 anti-mouse CD326 (Ep-CAM) G8.8 PG
Alexa Fluor® 700 anti-mouse CD326 (Ep-CAM) G8.8 FC
TotalSeq™-C0449 anti-mouse CD326 (Ep-CAM) G8.8 PG
Brilliant Violet 785™ anti-mouse CD326 (Ep-CAM) G8.8 FC
TotalSeq™-B0449 anti-mouse CD326 (Ep-CAM) G8.8 PG
Brilliant Violet 650™ anti-mouse CD326 (Ep-CAM) G8.8 FC
PE/Cyanine5 anti-mouse CD326 (Ep-CAM) G8.8 FC
Spark Red™ 718 anti-mouse CD326 (Ep-CAM) (Flexi-Fluor™) G8.8 FC
Spark Blue™ 574 anti-mouse CD326 (Ep-CAM) (Flexi-Fluor™) G8.8 FC
Spark Blue™ 550 anti-mouse CD326 (Ep-CAM) (Flexi-Fluor™) G8.8 FC
Go To Top Version: 1    Revision Date: 04.25.2019

For Research Use Only. Not for diagnostic or therapeutic use.

 

This product is supplied subject to the terms and conditions, including the limited license, located at www.biolegend.com/terms) ("Terms") and may be used only as provided in the Terms. Without limiting the foregoing, BioLegend products may not be used for any Commercial Purpose as defined in the Terms, resold in any form, used in manufacturing, or reverse engineered, sequenced, or otherwise studied or used to learn its design or composition without express written approval of BioLegend. Regardless of the information given in this document, user is solely responsible for determining any license requirements necessary for user’s intended use and assumes all risk and liability arising from use of the product. BioLegend is not responsible for patent infringement or any other risks or liabilities whatsoever resulting from the use of its products.

 

BioLegend, the BioLegend logo, and all other trademarks are property of BioLegend, Inc. or their respective owners, and all rights are reserved.

 

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.

ProductsHere

Login / Register
Remember me
Forgot your password? Reset password?
Create an Account