Alexa Fluor® 594 Donkey anti-rabbit IgG (minimal x-reactivity) Antibody

Pricing & Availability
Clone
Poly4064 (See other available formats)
Regulatory Status
RUO
Isotype
Donkey Polyclonal Ig
Poly4064_A594_IgG_Antibody_102820
HeLa cells were fixed with 2% paraformaldehyde (PFA) for 10 minutes, permeabilized with 0.5% Triton X-100 for 5 minutes, and blocked with 5% FBS for 30 minutes. Then the cells were intracellularly stained with 2.5 µg/ml of purified anti-BRCA1 (clone Poly26599) in blocking buffer overnight at 4°C, followed by 2.5 µg/ml of anti-rabbit IgG (clone Poly4064) Alexa Fluor° 594 (red) for 2 hours and Alexa Fluor® 488 Phalloidin (green) staining for 20 minutes at 4°C. Nuclei were counterstained with DAPI (blue). The image was captured with a 60X objective.
  • Poly4064_A594_IgG_Antibody_102820
    HeLa cells were fixed with 2% paraformaldehyde (PFA) for 10 minutes, permeabilized with 0.5% Triton X-100 for 5 minutes, and blocked with 5% FBS for 30 minutes. Then the cells were intracellularly stained with 2.5 µg/ml of purified anti-BRCA1 (clone Poly26599) in blocking buffer overnight at 4°C, followed by 2.5 µg/ml of anti-rabbit IgG (clone Poly4064) Alexa Fluor° 594 (red) for 2 hours and Alexa Fluor® 488 Phalloidin (green) staining for 20 minutes at 4°C. Nuclei were counterstained with DAPI (blue). The image was captured with a 60X objective.
Compare all formats See Alexa Fluor® 594 spectral data
Cat # Size Price Quantity Check Availability
406418 100 µg $141.00
Check Availability


Need larger quantities of this item?
Request Bulk Quote
Description

This polyclonal donkey anti-rabbit IgG antibody reacts with the heavy chains of rabbit IgG and with the light chains common to most rabbit immunoglobulins. No cross-reactivity has been detected against non-immunoglobulin serum proteins. This antibody has been solid-phase absorbed to ensure minimal cross-reaction with rat, human, bovine, horse, and mouse immunoglobulins, but it may cross-react with other subclasses of rabbit immunoglobulins.

Technical data sheet

Product Details

Verified Reactivity
Rabbit
Antibody Type
Polyclonal
Host Species
Donkey
Formulation
Phosphate-buffered solution, pH 7.2, containing 0.09% sodium azide.
Preparation
The antibody was purified by affinity chromatography and conjugated with Alexa Fluor® 594 under optimal conditions.
Concentration
0.5 mg/mL
Storage & Handling
The antibody solution should be stored undiluted between 2°C and 8°C, and protected from prolonged exposure to light. Do not freeze.
Application

ICC - Quality tested

Recommended Usage

Each lot of this antibody is quality control tested by immunocytochemistry. For immunocytochemistry, a concentration range of 1.0 - 5.0 µg/mL is recommended. It is recommended that the reagent be titrated for optimal performance for each application.

* Alexa Fluor® 594 has an excitation maximum of 590 nm, and a maximum emission of 617 nm.


Alexa Fluor® and Pacific Blue™ are trademarks of Life Technologies Corporation.

View full statement regarding label licenses
Excitation Laser
Green Laser (532 nm)/Yellow-Green Laser (561 nm)
Application Notes

This conjugated polyclonal donkey anti-rabbit IgG antibody is useful for immunofluorescent staining for flow cytometry, or microscopy.

Product Citations
  1. Kim D, et al. 2021. Anim Cells Syst (Seoul). 25:264. PubMed
  2. Chandler A, et al. 2022. J Orthop Res. 40:1918. PubMed
  3. Hermanns N, et al. 2022. Basic Res Cardiol. 117:52. PubMed
  4. Marques RM, et al. 2021. Cell Death Differ. 28:3140. PubMed
  5. Flommersfeld S, et al. 2021. Immunity. :. PubMed
  6. Wu W, et al. 2018. J Am Soc Nephrol. 29:168. PubMed
  7. Reinhardt R, et al. 2019. Development. 146:10. PubMed
  8. Jin LQ, et al. 2022. Cells. 11:. PubMed
  9. Kasagi Y, et al. 2016. Cancer Res . 76: 347 - 357. PubMed
RRID
AB_2563306 (BioLegend Cat. No. 406418)
Go To Top Version: 2    Revision Date: 10/28/2020

8999 BioLegend Way, San Diego, CA 92121 www.biolegend.com
Toll-Free Phone: 1-877-Bio-Legend (246-5343) Phone: (858) 768-5800 Fax: (877) 455-9587

This data display is provided for general comparisons between formats.
Your actual data may vary due to variations in samples, target cells, instruments and their settings, staining conditions, and other factors.
If you need assistance with selecting the best format contact our expert technical support team.